IOPA-3P32-N Optanium T8 Electronic Ballast

(No reviews yet) Write a Review
Was: $21.63
Now: $18.53
SKU:
IOPA3P32N35I
UPC:
781087124635
Condition:
New
Availability:
Shipping:
Calculated at Checkout
HS Tariff code:
8504.10.0000

Product Overview

Philips Advance IOPA3P32N 3-Lamp T8 Electronic Ballast

High-efficiency instant start electronic ballast with IntelliVolt technology. Operates 2-3 T8 lamps across 120-277V with superior energy efficiency, cold weather performance, and parallel lamp operation.

120-277V
IntelliVolt
2-3 Lamp
Capacity
2.89
B.E.F.
<15%
THD
-20°F
Min Start

Quick Specs

  • Brand: Philips Advance
  • Model: IOPA3P32N
  • Type: Electronic Instant Start Ballast
  • Voltage: 120-277V IntelliVolt
  • Lamp Capacity: 2-3 Lamps
  • B.E.F.: Up to 2.89
  • THD: Less than 15%
  • Power Factor: Greater than 0.98

Product Overview

The Philips Advance IOPA3P32N electronic ballast delivers professional-grade performance for T8 fluorescent lighting systems. Featuring IntelliVolt automatic voltage adjustment technology, this instant start ballast seamlessly operates across 120-277V input, simplifying inventory management and installation. The high Ballast Efficacy Factor (B.E.F.) of up to 2.89 delivers exceptional energy efficiency with total harmonic distortion below 15% and power factor exceeding 0.98.

Engineered for demanding commercial and industrial environments, this ballast provides reliable cold weather starting down to -20°F (-29°C). The parallel lamp connection ensures remaining lamps continue operating if individual lamps fail, minimizing maintenance disruptions. With striation-reduction technology, this ballast delivers smooth, flicker-free illumination ideal for spaces with long burn hours.

Why Choose This Ballast

  • IntelliVolt Technology: Automatic voltage sensing from 120-277V eliminates voltage-specific inventory
  • Superior Efficiency: B.E.F. up to 2.89 delivers 30% energy savings versus magnetic ballasts
  • High Power Quality: Less than 15% THD and greater than 0.98 power factor protect electrical systems
  • Cold Weather Ready: Reliable starting at -20°F for refrigeration and outdoor applications
  • Parallel Operation: Individual lamp circuits prevent total fixture failure
  • Instant Start: Immediate ignition ideal for spaces with extended operating hours
  • ASHRAE 90.1 Compliant: Meets energy standards and contributes to LEED certification

Technical Specifications

SpecificationValue
Brand Philips Advance
Model Number IOPA3P32N
Ballast Type Electronic Instant Start
Lamp Capacity 2-3 Lamps
Input Voltage 120-277V (IntelliVolt Auto-Sensing)
Ballast Efficacy Factor Up to 2.89
Total Harmonic Distortion Less than 15%
Power Factor Greater than 0.98
Circuit Type Parallel
Minimum Start Temp -20°F (-29°C)
Lead Length Pre-cut 24-43 inches
Special Features Striation-reduction technology

Dimensions

DimensionMeasurement
Length 9.5 inches
Width 1.3 inches
Height 1.0 inches
Profile Compact Low-Profile

Compatible Lamp Types

This Advance IOPA3P32N ballast operates the following T8 fluorescent lamps (2-3 lamps):

  • F17T8: 24-inch 17W T8 lamps
  • F25T8: 36-inch 25W T8 lamps
  • F25T8/ES: 36-inch 25W energy-saving T8 lamps
  • F28T8/ES: 48-inch 28W energy-saving T8 lamps
  • F32T8/ES: 48-inch 32W energy-saving T8 lamps
  • F32T8: 48-inch 32W standard T8 lamps
  • F40T8: 60-inch 40W T8 fluorescent lamps

Applications

  • Commercial office buildings
  • Industrial manufacturing facilities
  • Cold storage and refrigeration warehouses
  • Retail store lighting systems
  • Healthcare facility fluorescent fixtures
  • Educational institution lighting
  • Outdoor protected fixtures in cold climates
  • ASHRAE 90.1 compliance projects
  • LEED certification contributions

Replacing Your Current Ballast?

The Philips Advance IOPA3P32N is an ideal replacement for:

  • Magnetic T12 ballast systems (delivers 30% energy savings)
  • Standard efficiency electronic T8 ballasts
  • Failed instant start ballasts in 2 or 3-lamp T8 fixtures
  • Voltage-specific ballasts when universal voltage is needed

Before Ordering - Verify:

  • Fixture accepts 9.5" x 1.3" x 1.0" ballast enclosure
  • Existing lamps are compatible T8 types listed above
  • Input voltage falls within 120-277V range
  • Instant start wiring configuration is present
  • Application requires cold weather starting capability

Ordering Information

ItemDetails
Model IOPA3P32N
Description Advance 3-Lamp T8 Electronic Instant Start Ballast
Voltage 120-277V IntelliVolt
Start Type Instant Start

Compliance and Certifications

CertificationStatus
UL Type CC Safety Rating
ASHRAE 90.1 Compliant
LEED Contributes to Certification

Installation Notes

  • Parallel lamp connection keeps remaining lamps lit if one fails
  • Pre-cut leads (24-43") simplify wiring installation
  • Install in accordance with National Electric Code requirements
  • Verify instant start lampholder configuration
  • IntelliVolt technology automatically adjusts to line voltage

Contact ADL Supply for bulk pricing and project quotes. This Philips Advance ballast is stocked for immediate shipment to support your commercial lighting retrofit and maintenance needs.

Reviews

(No reviews yet) Write a Review