Product Overview

Sylvania QHE 4X32T8/UNVISHSC – 4-Lamp T8 High Ballast Factor Electronic Ballast | 1.15 BF | 120-277V | Programmed Rapid Start | Type 1 Outdoor
High ballast factor 1.15 with programmed rapid start technology – a high-efficiency electronic ballast for 3-4 T8 fluorescent lamps (25W–32W energy saving and standard), featuring Type 1 outdoor rating, Class A sound, and NEMA Premium compliance.
|
Input Voltage
120-277V
50/60Hz
|
Ballast Factor
1.15
High Output
|
Lamp Type
T8 / FO / FBO
3-4 Lamps
|
Sound Rating
Class A
Quietest
|
Outdoor Rating
Type 1
UL Class P
|
Quick Specs
- Brand: Sylvania (OSRAM)
- Model: QHE 4X32T8/UNVISHSC
- Ballast Type: Electronic – Programmed Rapid Start (PROStart)
- Input Voltage: 120-277V AC, 50/60Hz (dual voltage)
- Ballast Factor: 1.15 (high ballast factor)
- Circuit Type: Parallel
- Lamp Compatibility: 3-4 x FO32/25W (25W), 3-4 x FO32/28W (28W), 4 x FO30/SS (30W), 3-4 x F32T8 ECO (32W), 3-4 x FBO U-bend, 3 x FO40 (60")
- Maximum Case Temperature (tc): 70°C (158°F)
- Minimum Starting Temperature: -20°F (-29°C) standard; 60°F (16°C) with SS lamps
- Sound Rating: Class A
- THD: <10%
- Remote Mounting: Up to 20 feet
- Dimensions: 9.47" L x 1.69" W x 1.18" H (small can enclosure)
- Compliance: UL Class P Type 1 Outdoor, CSA, ANSI C82.11, FCC Part 18, Type CC, NEMA Premium, PCB-free
Product Overview
The Sylvania QHE 4X32T8/UNVISHSC is a high‑performance electronic ballast designed for 3‑4 T8 fluorescent lamps (25W–32W). With a high ballast factor of 1.15, it delivers increased light output – ideal for applications requiring higher illuminance, such as retail displays, task lighting, and industrial work areas. The ballast features programmed rapid start (PROStart) technology, which preheats cathodes before ignition to extend lamp life in frequently switched fixtures.
Operating on dual voltage 120‑277V, this ballast meets NEMA Premium requirements and qualifies for utility incentives. Its parallel circuit design ensures that if one lamp fails, the remaining lamps continue to operate. The ballast is Type 1 Outdoor rated and built in a compact small can enclosure (9.47″L x 1.69″W x 1.18″H) for easy installation in tight fixture spaces. Lamp striation control (LSC) minimizes or eliminates striations common in T8 energy‑saving lamps.
Why Choose This Product
- High ballast factor 1.15 – up to 15% more light: Ideal for retail, industrial, and task‑oriented applications requiring higher illumination levels.
- Programmed rapid start: Extends lamp life in areas with frequent switching (e.g., offices, classrooms, restrooms).
- Energy savings: Delivers 30‑60% energy savings compared to F34T12 magnetically ballasted systems; up to 6% (2‑5W) savings over standard electronic ballasts.
- Wide lamp compatibility: Supports 3‑4 energy‑saving and standard T8 lamps, plus U‑bend and 60″ FO40 lamps – reduces inventory complexity.
- Type 1 Outdoor rating: Suitable for damp/wet locations when installed in approved weatherproof fixtures.
- NEMA Premium compliant: Qualifies for utility incentives and meets the most stringent energy codes.
- Class A sound rating: Silent operation for noise‑sensitive environments.
- Lamp striation control (LSC): Eliminates unsightly striations in T8 energy‑saving lamps.
Technical Specifications
| Brand | Sylvania (OSRAM) |
| Model | QHE 4X32T8/UNVISHSC |
| Ballast Type | Electronic – Programmed Rapid Start |
| Input Voltage | 120-277V AC, 50/60Hz |
| Ballast Factor | 1.15 |
| Circuit Type | Parallel |
| Lamp Compatibility | 3-4 x FO32/25W, FO32/28W, F32T8 ECO, FBO U-bend; 4 x FO30/SS; 3 x FO40 |
| Max Case Temperature (tc) | 70°C (158°F) |
| Min Starting Temp (Standard) | -20°F (-29°C) |
| Sound Rating | Class A |
| THD | <10% |
| Remote Mounting | Up to 20 feet |
Dimensions
| Length | 9.47 in (240.5 mm) |
| Width | 1.69 in (42.9 mm) |
| Height | 1.18 in (30.0 mm) |
Applications
- Commercial lighting – offices, retail stores, conference rooms
- Industrial lighting – warehouses, manufacturing facilities, workbenches
- Educational facilities – classrooms, libraries, auditoriums
- Healthcare – hospitals, clinics, examination rooms
- Outdoor rated fixtures – parking garages, canopies, building exteriors (with proper enclosure)
Compatibility & Replacement
Fixture type: Designed for T8 fluorescent fixtures (linear and U‑bend) using 3 or 4 lamps. Compatible with F32T8 standard and energy-saving lamps, FO series, and FBO U‑bend lamps.
Ballast factor: 1.15 – delivers approximately 15% more light than normal ballast factor (1.0).
Before ordering, confirm:
- Lamp type: Verify your fixture uses one of the compatible T8 lamps listed above.
- Number of lamps: Ensure fixture uses 3 or 4 lamps (depending on lamp type).
- Input voltage: Confirm supply voltage is 120‑277V, 50/60Hz.
- Outdoor requirement: If installing outdoors, ensure fixture is weatherproof rated.
- Physical dimensions: Verify ballast fits within your fixture (9.47"L x 1.69"W x 1.18"H).
Ordering Information
- Brand: Sylvania (OSRAM)
- Model: QHE 4X32T8/UNVISHSC
- Description: 4‑lamp T8 programmed rapid start electronic ballast, 120‑277V, 1.15 ballast factor, Type 1 outdoor, Class A sound
- Case quantities and bulk pricing available – contact ADL Supply for volume orders.
Compliance & Certifications
- UL Listed – Class P, Type 1 Outdoor
- CSA Certified
- ANSI C82.11 Compliant
- FCC 47 CFR Part 18 Compliant (Non-Consumer)
- ANSI C62.41 Category A Transient Protection
- Type CC Rating per UL935
- NEMA Premium Electronic Ballast Program
- PCB‑Free Construction
ADL Supply recommends confirming all applicable compliance data with the Sylvania official product data sheet prior to specification or installation.
Safety & Installation Notes
- Disconnect power before installing or servicing.
- Ground ballast case in accordance with national and local electrical codes.
- Outdoor installation: Must be used in a UL‑listed weatherproof enclosure rated for Type 1 Outdoor.
- Lampholder must be shorted per diagram – refer to wiring diagram on ballast label.
- Maximum case temperature: Do not exceed 70°C (158°F).
- Minimum starting temperature: -20°F (-29°C) for standard lamps; 60°F (16°C) for SS lamps.
- Follow fixture manufacturer's instructions and local electrical codes for installation.