Product Overview

Philips 553248 10T8/COR/48-850/IF16/G/DIM 10/1 10W 48" T8 LED 5000K Daylight InstantFit Lamp
The Philips 553248 (10T8/COR/48-850/IF16/G/DIM 10/1) is a 10W 48" T8 LED InstantFit lamp from the Philips Energy Advantage CorePro line, rated for 5000K daylight light at 80 CRI (min). It ships with 1,600 nominal lumens and a 50,000-hour average rated life, and is designed as a direct plug-and-play replacement into existing T8 fixtures – no ballast bypass or rewiring required for compatible ballasts.
|
Wattage
10W
Bare Lamp
|
Color Temp
5000K
Daylight
|
Lumens
1,600
Nominal
|
UL Type
A, C
InstantFit
|
Rated Life
50,000
Hours
|
Technical Specifications
| Philips Product Number (6nc) | 553248 |
| Ordering Abbreviation | 10T8/COR/48-850/IF16/G/DIM 10/1 |
| Product Line | Philips Energy Advantage CorePro InstantFit |
| Lamp Length | 48" |
| Base | G13 Bi-Pin |
| Bare Lamp Watts | 10W |
| CRI (min) | 80 |
| Color Temperature | 5000K (Daylight) |
| Nominal Lumens | 1,600 lm |
| Beam Angle | 240° |
| Lamp Material | Glass |
| UL Type | A, C |
| Dimmable | Yes |
| Average Rated Life | 50,000 hours (B50 L70, tested at ballast factor ≤ 0.88) |
| DLC Listing | DLC Product ID P6YC6AM6 |
| System Watts by Ballast Factor | Low (0.78): 12W · Normal (0.88): 13W · High (1.18): 17.5W |
| System Lumens by Ballast Factor | Low (0.78): 1,450 lm · Normal (0.88): 1,600 lm · High (1.18): 2,100 lm |
| Standard Package Quantity | 10 per case |
| Mercury Content | Mercury-free (LED lamp) |
Product Overview
This Philips InstantFit lamp is proven compatible with over 350 ballasts and drivers – UL Type A models like this one are designed to work directly with existing instant-start, programmed-start, and programmed-start-dimmable ballasts already in the fixture, so there's no need to bypass or rewire the ballast in most retrofit installations. Actual system wattage and light output depend on the ballast factor of the specific ballast driving the lamp; the manufacturer publishes figures at low (0.78), normal (0.88), and high (1.18) ballast factor, shown in the spec table above.
The glass lamp body is rated for 50,000 hours to B50 L70 (the point at which half the LED sources have dropped below 70% of initial lumen output), tested at a ballast factor of 0.88 or lower. All InstantFit lamps carry a Stroboscopic Visibility Measure (SVM) below 1.0, meaning no perceivable flicker under NEMA77, IEC 61547, and IEC 63158 standards.
Compatible Applications
- Direct retrofit into existing T8 fixtures using compatible instant-start, programmed-start, or programmed-start-dimmable ballasts
- Commercial, retail, and office fixtures being converted from fluorescent to LED without full fixture replacement
- Applications requiring DLC-listed LED replacement lamps for utility rebate programs (where DLC Product ID is listed)
Before Ordering – Verify
- Confirm your existing ballast is on Philips' current InstantFit ballast compatibility list before ordering – not all ballasts are compatible, and compatibility is subject to change as more ballasts are tested
- Confirm lamp length (48") and wattage (10W) match your fixture
- If utility rebate documentation is required, confirm the DLC Product ID above is still active on the DLC QPL using the model number
- Confirm dimming requirements – this lamp is dimmable
Safety and Handling Guidelines
- Turn off power to the fixture before relamping
- Verify ballast compatibility before installation – installing on an incompatible or unlisted ballast can cause the lamp to fail to strike or perform erratically
- Handle by the base/end caps; avoid flexing or striking the lamp body
- Dispose of / recycle in accordance with local electronics waste regulations
Compliance
- Mercury-free LED lamp
- DLC Product ID P6YC6AM6
- UL Type A, C
- RoHS Compliant
Ordering Information
- Philips Product Number (6nc): 553248
- Ordering Abbreviation: 10T8/COR/48-850/IF16/G/DIM 10/1
- Manufacturer Part Number: 10T8/COR/48-850/IF16/G/DIM 10/1
- UPC: 046677553241
- Standard Package Quantity: 10 per case
For wholesale pricing, bulk availability, or help confirming ballast compatibility, contact ADL Supply at 1-800-235-3489.