Product Overview

Official Osram Entertainment Lighting Logo - ADL Supply

Osram Xenophot® 54250 (64633 HLX) Halogen Lamp — 150W | 15V Low Voltage | 5,600 Lumens | G6.35 Bi-Pin Base

The Osram Xenophot® Professional 54250 (64633 HLX) Lamp is an entertainment and medical-grade, high-intensity low-voltage tungsten halogen capsule engineered exclusively for laboratory microscopes, ophthalmic slit lamps, surgical diagnostic instruments, dental examination tracks, and high-magnification overhead slide projection systems. Delivering 5,600 initial lumens of crisp 3300K studio white illumination, this premium single-ended bulb features an authoritative ANSI BRJ / LIF A1/234 specification tracking profile and utilizes an advanced Xenophot (HLX) fill gas matrix—where high-pressure xenon gas replaces traditional krypton—to achieve up to 10% higher luminous efficiency while maintaining standard power parameters. Outfitted with a heavy-duty G6.35 bi-pin base and a high-purity clear T4 quartz glass envelope, it ensures perfect optical focal alignment across its 50-hour calibrated technical service life.

Power Draw
150W / 15V
Low-Voltage Required
Brightness
5,600 lm
Xenophot Flux
Color Temp
3300K
Studio White
Interface
G6.35
6.35mm Pin Pitch
ANSI Code
BRJ
Specialty Optic

ADL Supply Expert Application & Replacement Guide

The Osram 64633 HLX low-voltage technical capsule is an established medical, clinical laboratory, and photographic baseline specified universally across clinical diagnostics bays, automated blood chemistry analyzers, surgical examination monitors, and high-contrast material inspection stations. Featuring a precision-aligned flat planar filament positioned perfectly within its clear transparent casing, this lamp delivers an intense full-spectrum point light beam. This allows laboratory pathologists, ophthalmic surgeons, and material quality technicians to capture absolute color rendering accuracy and fine structural depth without experiencing the frequency gaps or visual color casting common in alternative solid-state replacements.

Critical 15V Low-Voltage Transformer Parameters and G6.35 Seating Safety Controls: Facility engineers and medical field contractors executing routine instrument maintenance must verify circuit configuration metrics closely prior to checkout: this capsule runs natively on low-voltage 15V line tracks and requires a compatible step-down magnetic transformer or stabilized electronic DC power supply to operate safely. Connecting or bridging this 15V module directly across standard 120V or 277V primary building branch circuits will trigger instant high-amperage over-drive failure, prompting immediate filament vaporization and an explosive quartz capsule breakdown.

Furthermore, ensure the dual pins—spaced on an absolute 6.35mm center-to-center pitch—slide fully and straight into the fixture socket blocks. Because driving a high thermal density 150-watt load across a compact G6.35 contact footprint requires minimum line resistance, any loose wire contact or internal pin tracking will invite localized arcing loops, causing high contact resistance that transcends the base's maximum safe **350°C maximum safe thermal limit** and damages the host instrument's delicate socket assembly.

Verify Before Installing
Strict s90 Burn Position — Enclosed Fixture Housing Mandatory — 100% Mercury-Free Exemption
This industrial capsule tracks a strict s90 burning orientation restriction, requiring vertical operation with the base pointing downward within a ±90-degree allowed tilt variance. Operating outside this structural boundary prompts catastrophic filament sag and premature seal breakdown. Measures exactly 44.0mm ($1.73\text{ Inches}$) in Maximum Overall Length (MOL) with a Light Center Length (LCL) of 30.0mm ($1.18\text{ Inches}$)—verify your instrument's optical lens alignment clearance before installing to prevent focal path drift. Never handle the raw quartz bulb capsule with bare fingers; body oils decompose at extreme operating temperatures, etching into the quartz glass to create thermal hotspots that prompt premature glass clouding or casing fracturing. Clean with an alcohol wipe if accidental contact occurs.

Mercury Compliance and Shipping Notice: This product is a filament-based tungsten halogen thermal capsule and contains 0.0 mg of mercury. It is completely exempt from regional state hazardous substance shipping bans and can be legally sold and shipped to all 50 states (including California, Vermont, and Oregon). No special hazardous materials handling or manifest tracking is required for standard commercial transit.

Detailed Product Specifications

  • Brand Name: OSRAM (OSRAM Sylvania Display/Optic Specialty Lighting Division)
  • Product Series Line: Xenophot® (HLX) Low-Voltage Single-Ended Specialty Halogen Family
  • Sylvania / NAED Factory Product Order Code SKU: 54250
  • Osram Factory Catalog Order Identification Number: 64633 HLX
  • Official Industry ANSI Equipment Code: BRJ
  • Official International LIF Specification Code: A1/234
  • UPC Barcode Number (GTIN-12): 046135542503
  • Global Trade Logistics Code (GTIN-13): 0046135542503
  • Alternate Stock Product Identifiers: 64633HLX, 4050300006710, 4055562141505
  • Core Technology Class: Thermal Incandescent — High-Pressure Xenon-Filled Tungsten Halogen Capsule
  • Primary Control Requirement: Step-Down Low-Voltage Transformer (15V Regulated Power Supply Output)
  • Operational Power Draw: 150 Watts
  • Nominal System Operating Voltage: 15.0 Volts AC/DC Low-Voltage Baseline
  • Continuous Operating Amperage Draw: 10.00 Amperes continuous line current load
  • Initial Luminous Brightness: 5,600 Lumens (Post standard factory seasoning burn)
  • Systemic Luminous Efficacy: 37.3 Lumens per Watt (LPW)
  • Color Temperature Configuration: 3300K Studio White (Clear Transparent Optical High-Purity Casing)
  • Color Rendering Index (CRI): 100 Ra (Flawless Continuous Full-Spectrum Energy Distribution)
  • Base Type Configuration: G6.35 Bi-Pin Base (Solid copper 2-pin formatting with 6.35mm pin pitch)
  • Maximum Base Shell Temperature Limit: 350°C (662°F Maximum Safe Surface Threshold)
  • Maximum Bulb Wall Operating Temperature: 900°C (1652°F Outer Chamber Heat Limit)
  • Bulb Shape Enclosure Code: T4 Enclosure Shape (11.5mm actual outer quartz glass casing width)
  • Maximum Overall Length (MOL): 44.0mm / 1.73" Inches Structural Body Height Base-to-Tip
  • Light Center Length (LCL Dimension): 30.0mm / 1.18" Inches Precision Focal Height Axis Center
  • Filament Dimensions: 4.8mm actual width x 3.0mm actual height focal field profile
  • Rated Average Service Lifespan: 50 Hours (Calibrated high-intensity performance target threshold)
  • Chassis Burn Position Limit: s90 Position (Vertical base-down & horizontal ±90° allowed tilt)
  • Fixture Safety Rating: Suitably Enclosed Halogen Luminaires Only Mandatory (Strict fragmentation containment control)
  • Manufacturing Craftsmanship Location: Certified Precision Manufacturing Track Made in Germany

Operation, Safety & Mounting Compliance

High-Temperature Regenerative Halogen Halide Cycle Controls

This halogen lamp operates via an internal chemical loop where vaporized tungsten particles bond with halogen gas molecules inside the heated chamber. This compound cycles back onto the burning filament tracks, redepositing the tungsten to preserve filament mass. For this cycle to work cleanly and prevent wall-blackening, the inner envelope must continuously transcend a high temperature threshold exceeding 250°C, making proper convective venting inside track cylinders or medical instrument shrouds mandatory.

Commercial Scientific Equipment Industry Cross-References

This standard 150W 15V G6.35 halogen bulb serves as a direct drop-in replacement or alternative for the following lines:

  • Philips Lighting Match: Focusline 150W 15V G6.35 / Technical Reference Code 7724XHP
  • Ushio Alternative Match: JC15V-150W Specialty Photo-Optic Line / Factory Order Code Reference
  • Eiko Reference Match: Eiko 03220 BRJ 15V 150W Clear Precision Lamp
  • Microscope Instrument Compatibility: Directly interfaces with various standard medical diagnosis decks, sub-stage microscope lighting brackets, and scientific film analyzers

Bulk Commercial Lighting Supply & Project Support

ADL Supply delivers commercial-volume logistical fulfillment, tiered commercial contractor discounting strategies, and full pallet project quoting options to electrical accounts across the United States.

For formal wholesale inquiries, volume pricing modifications, or manufacturer spec sheet documentation, reach our commercial branch directly at 1-800-235-3489. We are your commercial supply partners as an authorized wholesale Lighting Distributor In Doral, Florida.


Safety and Installation Guidelines

  • Use only in approved enclosed halogen fixtures
  • Disconnect power before installing or removing lamp
  • Allow lamp to cool before handling
  • Use clean gloves or lint-free cloth to avoid quartz contamination
  • Confirm correct system voltage before operation

Additional Information

In the Osram Xenophot version, xenon is used as the filling gas instead of standard fill gas technology. This allows the lamp to achieve up to 10% higher luminous efficiency while maintaining the same power consumption. Xenophot lamps are identified by the HLX abbreviation in the product catalog.