Product Overview

GE ETC Quartzline Halogen Lamp – Q150CL/DC 150W 120V SSTV Stage & Studio | ANSI ETC | 2950K | 2,800 Lumens | BA15d Base | 2000 hr Life
2,800 lumens at 2950K with CRI 100 and 2000-hour long life – a 150W/120V Quartzline halogen SSTV lamp with BA15d double contact bayonet base, clear T-4 bulb, and CC-8 filament for stage, studio, and broadcast lighting applications.
|
Wattage / Voltage
150W / 120V
Quartzline Halogen
|
ANSI Code
ETC
SSTV Stage
|
Initial Lumens
2,800
lm
|
Color Temp
2950K
Warm White
|
Base Type
BA15d
Double Contact Bayonet
|
Quick Specs
- Brand: GE Lighting
- Series: Quartzline
- Model / Order Code: Q150CL/DC
- Product Code: 43693
- Reorder Code: BC1534
- ANSI Code: ETC
- Lamp Type: Quartzline Halogen (SSTV)
- Wattage: 150 W
- Voltage: 120 V
- Base Type: BA15d (Double Contact Bayonet)
- Bulb Shape: T-4
- Bulb Finish: Clear
- Color Temperature: 2950K
- CRI: 100
- Initial Lumens: 2,800 lm
- Rated Average Life: 2,000 hours
- Filament Type: CC-8
- Burn Position: Universal
- Maximum Overall Length (MOL): 2.500 in (63.5 mm)
- Bulb Diameter: 0.500 in (12.7 mm)
- Light Center Length (LCL): 1.375 in (34.9 mm)
Product Overview
The GE 43693 Q150CL/DC is a professional Quartzline SSTV halogen lamp engineered for stage, studio, and entertainment lighting applications. Operating at 150 watts and 120 volts, this lamp delivers approximately 2,800 initial lumens with a 2950K warm color temperature and CRI 100, making it suitable for professional production environments where accurate color rendering and reliable output are essential.
Built with a durable CC-8 filament and GE Quartzline halogen technology, the ETC lamp provides stable light output and consistent performance for theatrical fixtures, broadcast lighting equipment, and studio luminaires. The BA15d double contact bayonet base ensures secure installation, while the 2,000-hour rated life significantly reduces maintenance frequency. The universal burn position allows installation in base-up, base-down, or horizontal fixtures.
Why Choose This Product
- 2,800 lumens – efficient 150W halogen output: Ideal for medium-throw stage fixtures, key lighting, and fill applications in studios and theaters.
- 2,000-hour long life – low maintenance: Extended service life reduces relamping costs and downtime.
- ANSI ETC – industry-standard replacement: The ETC code ensures consistent electrical and photometric performance for compatible fixtures.
- 2950K warm white color temperature: Provides a natural, warm tungsten ambiance suitable for theatrical and studio environments.
- CRI 100 – perfect color rendering: Full-spectrum halogen light ensures accurate color reproduction for film, video, and live events.
- BA15d double contact bayonet base: Secure, twist-lock base commonly found in professional stage and studio fixtures.
- Universal burn position: Works in any orientation – base-up, base-down, or horizontal.
Technical Specifications
| Brand | GE Lighting |
| Model / Product Code | 43693 / Q150CL/DC |
| Reorder Code | BC1534 |
| ANSI Code | ETC |
| Lamp Type | Quartzline Halogen (SSTV) |
| Wattage | 150 W |
| Voltage | 120 V |
| Base Type | BA15d (Double Contact Bayonet) |
| Bulb Shape | T-4 |
| Bulb Finish | Clear |
| Color Temperature | 2950K |
| CRI | 100 |
| Initial Lumens | 2,800 lm |
| Rated Average Life | 2,000 hours |
| Filament Type | CC-8 Coiled Coil |
| Burn Position | Universal |
Dimensions
| Maximum Overall Length (MOL) | 2.500 in (63.5 mm) |
| Bulb Diameter | 0.500 in (12.7 mm) |
| Light Center Length (LCL) | 1.375 in (34.9 mm) |
Applications
- Stage lighting fixtures – ellipsoidal spotlights, Fresnel luminaires
- Studio lighting systems – key, fill, and backlighting for television and video production
- Theater lighting equipment – front-of-house and on-stage fixtures
- Broadcast and production lighting
- Professional entertainment lighting – concerts, live events, and touring productions
Compatibility & Replacement
Fixture type: This ANSI ETC lamp fits professional stage and studio fixtures designed for a BA15d double contact bayonet base and 150W/120V halogen lamps. Common in smaller ellipsoidal spotlights, Fresnel fixtures, and specialty luminaires from manufacturers such as Altman, Strand, and Kliegl.
Base: BA15d – double contact bayonet base with two side pins. To install, push in and twist clockwise. Confirm your fixture uses BA15d lampholders (not single contact or screw bases).
Ballast: No ballast required – operates directly on 120V mains power.
Before ordering, confirm:
- ANSI code – ETC: Verify your fixture specifies ANSI ETC or equivalent 150W/120V halogen lamp.
- Voltage – 120V: Verify fixture and supply circuit are 120V.
- Base type – BA15d: Physically inspect your existing lamp or fixture lampholder to confirm BA15d base.
- Physical dimensions: Verify your fixture accepts a T-4 bulb with 2.500-inch overall length and 0.500-inch diameter.
- Fixture wattage rating: Ensure fixture is rated for at least 150W.
- Burn position – universal: This lamp works in any orientation, but always follow fixture manufacturer guidelines.
Ordering Information
- Brand: GE Lighting
- Product Code: 43693
- Reorder Code: BC1534
- Model / Order Code: Q150CL/DC
- ANSI Code: ETC
- Lamp Type: 150W/120V Quartzline Halogen – BA15d Base, Clear T-4, 2950K, 2,800 lm, 2,000 hr life, universal burn
- Case quantities and bulk pricing available – contact ADL Supply for volume orders.
Compliance & Certifications
- Verify UL / ETL listing status with manufacturer specification sheet.
- Verify RoHS compliance status with manufacturer specification sheet.
- Verify FDA radiation performance compliance with manufacturer specification sheet.
- Verify Prop 65 warning requirements with manufacturer specification sheet.
ADL Supply recommends confirming all applicable compliance data with the GE official product data sheet (ANSI ETC / Product Code 43693) prior to specification or installation.
Safety & Handling Notes
- High pressure warning – face shield required: Quartzline halogen lamps operate under high internal pressure. Always wear a face shield and protective gloves during handling and installation. Lamp burst can cause serious injury.
- No bare hands: Never touch the quartz envelope with bare skin. Oils cause hot spots leading to premature failure or lamp burst. Use clean gloves or a lint-free cloth.
- Do not exceed rated voltage: Operating above 120V dramatically shortens lamp life. Verify supply voltage before installing.
- Burn position – universal: This lamp is rated for universal operation, but always follow your fixture manufacturer's specified orientation.
- Extreme heat and UV output: Use only in approved enclosed luminaires with appropriate UV filtering.
- Allow complete cool-down before handling: Allow lamp to cool completely before relamping. Do not touch immediately after switching off.
- Follow your fixture manufacturer's service documentation for lamp replacement procedures.