Universal B454PUNV-E

(No reviews yet) Write a Review
$87.83
SKU:
UNB454PUNV-E
Condition:
New
Availability:
stock
Shipping:
Calculated at Checkout

Product Overview

Universal Lighting Technologies Logo

Universal AccuStart5 B454PUNV-E – 1–4 Lamp F54T5HO / 3–4 Lamp FT50W or FT55W | 120–277V | Programmed Rapid Start

The Universal AccuStart5 B454PUNV-E is a universal-voltage programmed rapid-start electronic ballast designed to operate one through four F54T5HO lamps, three or four FT50W/2G11 lamps, or three or four FT55W/2G11 lamps. It accepts 120–277V AC input at 50/60Hz, uses active power-factor correction, supports series-parallel lamp operation, and incorporates automatic-reset end-of-lamp-life shutdown circuitry. The ballast also supports selected lamp-switching configurations through its control leads. Please verify ballast model, lamp family, lamp quantity, wiring diagram, input voltage, dimensions, and fixture grounding before ordering.

Lamp Families
T5HO / 2G11
F54, FT50, FT55
Lamp Count
1–4
Varies by Lamp Type
Input Voltage
120–277V
50/60Hz
Start Type
Programmed
Rapid Start
Warranty
3 Years
From Manufacture

Technical Specifications

Manufacturer Universal Lighting Technologies
Product Family AccuStart5
Model Number B454PUNV-E
Ballast Type Electronic fluorescent ballast
Starting Method Programmed rapid start
Lamp Operation Series-parallel
Input Voltage 120–277V AC, ±10%
Input Frequency 50/60Hz
Power-Factor Correction Active power-factor correction
End-of-Life Protection Automatic-reset end-of-lamp-life shutdown circuitry
Lamp Switching Supports manufacturer-defined switching configurations through SW control wiring
Minimum Starting Temperature 0°F / -18°C
Minimum Starting Temperature Without Remote Mounting -20°F / -29°C
Maximum Case Temperature 194°F / 90°C
Sound Rating A
Remote Mounting Up to 20 ft
Mounting Length 16.28 in / 413.5 mm center-to-center
Overall Length 16.88 in / 428.8 mm
Width 1.82 in / 46.2 mm
Height 1.18 in / 30.0 mm
Weight 2.50 lb / 1.10 kg
Carton Quantity 10 pieces
Warranty 3 years from date of manufacture under normal conditions of use
Country / Region of Manufacture Manufactured in North America

Compatible Lamps and Electrical Performance

Lamp Type Lamp Count 120V Input Watts 277V Input Watts Ballast Factor
F54T5HO 4 235W 229W 1.00
F54T5HO 3 184W 182W 1.05
F54T5HO 2 122W 121W 1.00
F54T5HO 1 65W 65W 1.05
FT55W/2G11 4 229W 223W 0.90
FT55W/2G11 3 174W 171W 0.93
FT50W/2G11 4 240W 235W 1.10
FT50W/2G11 3 179W 177W 1.13

Key Features & Benefits

  • Operates one through four F54T5HO lamps from a single ballast.
  • Also supports three or four FT50W/2G11 or FT55W/2G11 long compact fluorescent lamps.
  • Universal 120–277V input simplifies use across commercial and industrial electrical systems.
  • Programmed rapid start helps support lamp life in frequently switched applications.
  • Automatic-reset end-of-lamp-life shutdown circuitry protects the ballast and fixture after lamp failure.
  • Active power-factor correction supports high power-factor operation across approved lamp combinations.
  • Series-parallel lamp operation supports the manufacturer’s documented multi-lamp switching configurations.
  • Remote mounting is permitted up to 20 feet where the application and wiring comply with manufacturer requirements.

Product Overview

The Universal AccuStart5 B454PUNV-E is designed for high-output T5 and long compact fluorescent fixtures that require flexible lamp-count operation and universal input voltage. It can power one, two, three, or four F54T5HO lamps, making it suitable for multi-lamp commercial fixtures and maintenance replacements where the original wiring and lamp configuration match the Universal diagram.

The ballast also supports three- and four-lamp FT50W/2G11 and FT55W/2G11 systems. Because ballast factor and input wattage vary by lamp family and lamp count, the exact fixture configuration must be verified rather than assuming all supported lamps operate identically.

Manufacturer wiring diagrams show selectable lamp switching using the grey lead and an external switch, occupancy sensor, relay, or other approved control device. When switching is not used, the specified control leads must be connected according to the Universal wiring instructions.

Compatible Applications

  • Four-lamp F54T5HO high-bay and commercial fixtures
  • One-, two-, three-, or four-lamp T5HO luminaires
  • Three- or four-lamp FT50W/2G11 fixtures
  • Three- or four-lamp FT55W/2G11 fixtures
  • Commercial warehouses and industrial facilities
  • Retail, institutional, and large-area fluorescent lighting
  • Maintenance replacement and ballast retrofit projects requiring B454PUNV-E compatibility
  • Fixtures using approved lamp-switching or occupancy-control configurations

Before Ordering – Verify

  • Model number: Confirm the required ballast is B454PUNV-E.
  • Lamp family: Verify the fixture uses F54T5HO, FT50W/2G11, or FT55W/2G11 lamps.
  • Lamp quantity: F54T5HO configurations support one through four lamps; FT50W and FT55W configurations support three or four lamps only.
  • Input voltage: Confirm the branch circuit is within 120–277V AC, ±10%, 50/60Hz.
  • Wiring: Compare the fixture wiring to the manufacturer diagram before disconnecting the original ballast.
  • Lamp switching: Verify whether the fixture uses the SW control circuit. Do not leave control leads incorrectly connected.
  • Three-lamp wiring: The manufacturer instructs installers to cap the specified unused Blue/White or Orange lead individually.
  • Dimensions: Confirm 16.88-inch overall length, 1.82-inch width, 1.18-inch height, and 16.28-inch mounting centers.
  • Case temperature: Verify that fixture thermal conditions keep the ballast case at or below 90°C.
  • Remote mounting: Remote installation is limited to 20 feet unless Universal approves another configuration.
  • Cross-references: Do not substitute GE, Philips Advance, Sylvania, Keystone, Hatch, or Robertson models solely by published cross-reference; verify lamp operation, ballast factor, dimensions, lead layout, and switching functions.

Safety and Installation Guidelines

  • The ballast must be grounded.
  • Disconnect branch-circuit power before inspecting, wiring, installing, or removing the ballast.
  • Follow the Universal wiring diagram for the exact lamp family and lamp-count configuration.
  • Do not connect unsupported lamp types or lamp quantities.
  • Use listed connectors and wire methods that comply with the National Electrical Code and local requirements.
  • Cap all unused leads individually as directed by the manufacturer.
  • Maintain proper fixture ventilation and do not exceed the 90°C maximum case temperature.
  • Use only approved switches, occupancy sensors, relays, or control devices for the SW lamp-switching circuit.
  • Do not install a ballast that shows physical damage, overheating, or damaged leads.
  • Professional installation by qualified electrical personnel is recommended.

Compliance

  • Meets ANSI C82.11-1993.
  • Meets ANSI C62.41-1991.
  • Meets FCC Part 18 Class A non-consumer limits for EMI and RFI.
  • UL listed: Class P, Type 1 Outdoor, Type HL.
  • CSA certified.
  • No PCBs.
  • No DLC, ENERGY STAR, Title 20, Title 24, or JA8 certification applies to this fluorescent ballast based on the supplied manufacturer sheet.

Ordering Information

  • Manufacturer: Universal Lighting Technologies
  • Series: AccuStart5
  • Model: B454PUNV-E
  • Input Voltage: 120–277V AC
  • Starting Method: Programmed rapid start
  • F54T5HO Lamp Quantity: 1–4 lamps
  • FT50W/2G11 Lamp Quantity: 3–4 lamps
  • FT55W/2G11 Lamp Quantity: 3–4 lamps
  • Carton Quantity: 10 pieces
  • Warranty: 3 years from date of manufacture

For wholesale pricing, bulk availability, or help confirming the correct replacement ballast, contact ADL Supply at 1-800-235-3489.

Reviews

(No reviews yet) Write a Review