The Ushio 1000605 FSH JCV120V-125WB is a 125W 120V single-ended halogen JC photo-optic and SSTV lamp engineered for professional audio/visual projection, studio lighting, stage spotlights, and photo-optic equipment. Delivering 3000K warm white output at 100 CRI through a G5.3 2-pin bi-pin base, this ANSI FSH-coded lamp provides a 200-hour calibrated service life in approved enclosed optical fixture assemblies — with a base-down only burn position restriction.

Wattage
125W
120V Halogen
Voltage
120V
Line Voltage
Color Temp
3000K
100 CRI
Base
G5.3
ANSI FSH
Rated Life
200 Hr
Base Down Only

ADL Supply Expert Application & Replacement Guide

The Ushio FSH JCV120V-125WB (Catalog 1000605) is primarily used by AV equipment technicians, studio lighting service teams, and stage lighting personnel as the replacement lamp in 125W 120V projectors, studio fixtures, stage spotlights, and photo-optic equipment where the ANSI FSH code is the equipment specification. This lamp operates on standard 120V line voltage — no transformer is required. The /B suffix in the lamp designation indicates base-down burn position only — this lamp must be installed with the base (pins) pointing downward; horizontal or base-up mounting is not approved and will affect filament orientation and lamp life at these operating temperatures. The G5.3 2-pin bi-pin base uses standard 5.3mm round pin spacing — confirm the fixture socket is G5.3 before ordering. The 200-hour calibrated service life is a precision parameter of the high-output photo-optic halogen platform — production and studio facilities should track runtime hours and maintain a replacement inventory to avoid lamp failure during active shoots or performances.

Before You Order

Verify Before Ordering
Base-Down Burn Position Only — Not Universal | G5.3 Socket | Confirm ANSI FSH | Enclosed Fixture Required
This lamp is approved for base-down burn position only — horizontal or base-up mounting is not permitted. Confirm your fixture installs this lamp with the base pointing downward. Confirm ANSI code FSH matches your equipment specification. Confirm G5.3 bi-pin socket. Enclosed fixture required. Allow 15-minute cool-down before relamping.

Detailed Product Specifications

  • Brand: Ushio
  • Product Line Series: Halogen JC Single-Ended Photo-Optic / SSTV
  • Lamp Designation: JCV120V-125WB
  • Ushio Catalog Number: 1000605
  • ANSI Code: FSH
  • UPC Barcode: Confirm with Ushio specification sheet
  • Core Technology: Tungsten-Halogen JC Single-Ended Photo-Optic
  • Wattage: 125W
  • Operating Voltage: 120V
  • Color Temperature (CCT): 3000K Warm White
  • Color Rendering Index (CRI): 100 Ra
  • Base Type Configuration: G5.3 2-Pin Bi-Pin (5.3mm round pin spacing)
  • Rated Average Lifespan: 200 Hours (Calibrated)
  • Burn Position: Base Down Only — horizontal and base-up not approved
  • Mercury Content: None — standard e-waste disposal applies

Operation, Safety & Mounting Compliance

Base-Down Burn Position, 120V Line Voltage & Quartz Handling

The base-down burn position restriction is encoded in the "/B" suffix of the lamp designation JCV120V-125WB — the lamp's filament is designed to operate with the base (pins) pointing downward relative to gravity. Operating this lamp in a horizontal or base-up position causes the filament to sag under gravity in a different plane than its design geometry, creating hot spots that accelerate premature envelope failure at these operating temperatures. Confirm the fixture and mounting bracket orient the lamp base-down before installation. This lamp operates on standard 120V line voltage — no transformer is required; verify supply voltage before installation. Never handle the quartz envelope with bare skin — skin oils create localized hot spots that accelerate premature envelope failure. If skin contact occurs, clean with isopropyl alcohol before powering the fixture. Allow a minimum 15-minute cool-down before relamping.

Industry Cross-Reference Data

  • Osram Sylvania: 54436 FSH 125W 120V G5.3 (equivalent ANSI FSH halogen JC photo-optic)
  • Philips: FSH 125W 120V G5.3 (equivalent ANSI FSH single-ended halogen)
  • Legacy Cross-Reference: Direct replacement for ANSI FSH-coded 125W 120V G5.3 single-ended halogen lamp positions in professional AV projection, studio, and stage fixture hardware requiring base-down installation