GE 63051 GEMH250MVA-F

(No reviews yet) Write a Review
$163.47
SKU:
GEL63051
UPC:
43168630511
Availability:
3-5 Business Days lead time for delivery
Shipping:
Calculated at Checkout
HS Tariff code:
8504.10.0000

Product Overview

GE Lighting Logo

GE 63051 GEMH250MVA-F

The GE 63051 GEMH250MVA-F is a GE Enclosed and Potted Metal Halide F-Can ballast. It is a Magnetic – F-Can ballast designed to operate 1 – 250W M58 120/277 Enclosed and Potted F-Can lamp configuration, with 120/277 dual-voltage input and HX-HPF circuit type. This model is the current-production replacement for GE ballast 86564 (1110246CTC000C, 250W M58); per GE's F-Can transition plan, it is a direct functional substitute for that part.

This ballast should be selected by matching the GE order code, ANSI lamp code, wattage, input voltage, wiring diagram, and case dimensions to the existing ballast or fixture label.

Wattage
250W
Metal Halide
Voltage
120/277
Dual Voltage
ANSI Code
M58, H37
Lamp Code
Circuit Type
HX-HPF
HID Ballast
Ballast Type
Magnetic
F-Can

Product Overview

GE Enclosed and Potted Metal Halide F-Cans combine the rugged durability and efficiency of high intensity discharge ballasts with the user-friendly envelope of a standard fluorescent-style ballast case, allowing for easier handling and mounting in exterior applications. GE F-Cans are made from high-grade steel laminations and tightly wound, vacuum-impregnated copper coils for superior heat dissipation and water resistance, encased in potting material for additional heat sinking and weather resistance, and secured in a durable white steel powder-coated box for corrosion protection and long life. This construction gives GE F-Cans cooler operating temperatures and better sound attenuation than standard core-and-coil ballasts, making them well suited to remote-mounted, indoor, and outdoor HID applications.

Technical Specifications

BrandGE Lighting
GE Order Code63051
ModelGEMH250MVA-F
Ballast TypeMagnetic – F-Can
ANSI Lamp Code(s)M58, H37
Circuit TypeHX-HPF
Input Voltage120/277
Line Voltage Regulation±5%
Supply Current Frequency60 Hz
Insulation Class90C
Capacitor Temperature Rating100°C (212°F)
Sound RatingC (31-36 decibels)
Additional InfoThermally Protected
Coil Material (Pri/Sec)CU/CU
Dimensions (L x W x H)16.6 in (422 mm) x 3.2 in (81 mm) x 2.7 in (70 mm)
Mounting Length16.1 in (410 mm)
Mounting Width2.0 in (51 mm)
Mounting Slots0.2 in (6 mm)
Weight17.50 lbs
Exit TypeSide
Lead LengthsBlack and White, Red, Black/Yellow – 12 in (305 mm) each
Wiring Diagram ReferenceHID H34
Case Drawing ReferenceFCAN3
Items per Sales Unit / Standard Package1 / 2

Specifications by Line Voltage – Lamp: M58, H37 – 250W Quartz Metal Halide / 175W Quartz Metal Halide / 250W Mercury

Specification120V277V
System Wattage (W)319312
Nominal Current2.50 A1.10 A
Ballast Factor11
Ballast Efficiency Factor0.850.85
Max Input CurrentSee mfr. specsSee mfr. specs
Starting CurrentSee mfr. specsSee mfr. specs
Open Circuit Voltage280V280V
Drop Out Voltage96V222V
Power Factor≥90%≥90%
Min. Starting Temperature-22°F / -30°C-22°F / -30°C
Fuse Rating84
Safety ListingcUL ListedUL Listed

Key Features

  • Dual Voltage 120/277V 60 Hz input.
  • Igniter and capacitor mounted within the ballast case.
  • Ideal for external use – UL & cUL 1029 Listed for Type 1 indoor & outdoor applications.
  • Class A Insulation Material – 105°C/221°F rating, 90°C/194°F max case temperature.
  • Reliable low-temperature starting down to -22°F.
  • Standard F-Can dimensions equivalent to competitive offerings for ease of retrofit.
  • Integral thermal protector provides system protection in the event of overload or failure.
  • 2 year limited warranty.

Compatible Applications

  • Commercial and office lighting
  • Retail lighting
  • Education – schools and auditoriums
  • Museum and landmark lighting
  • Down-lighting
  • Indirect lighting

Before Ordering Verify

  • Exact GE Model: Match GE 63051 / GEMH250MVA-F to the existing ballast label or fixture documentation.
  • ANSI Lamp Code: Confirm the fixture lamp is coded M58, H37.
  • Wattage: Confirm the lamp wattage matches 250W.
  • Input Voltage: Confirm the fixture supply matches 120/277.
  • Wiring Diagram: Follow HID H34 on the ballast label and verify socket/lamp holder type before installation.
  • Case Size: Confirm the ballast channel has room for the 16.6 in (422 mm) x 3.2 in (81 mm) x 2.7 in (70 mm) case (mounting length 16.1 in (410 mm)).
  • Cross-Reference: If replacing GE 86564 (1110246CTC000C, 250W M58), confirm this current-production model is the correct direct substitute for your fixture.

Safety & Installation Guidelines

  • Qualified Installation: Ballasts should be installed by qualified personnel following applicable electrical codes.
  • Disconnect Power: Turn off and lock out power before removing or installing a ballast.
  • Grounding: Properly ground the ballast and fixture to reduce EMI/RFI and support safe operation.
  • Wiring Diagram: Follow HID H34 exactly; incorrect wiring can prevent starting or damage the ballast and lamp.
  • Remote Mounting: When remote mounting, keep lead length and wire gauge within the manufacturer's listed remote mounting distance and wire gauge for this model.
  • Enclosure Integrity: Confirm the potted enclosure and gasket/case seal are intact before installing in outdoor or wet-location fixtures.

Wholesale & Project Support

ADL Supply supports contractors, facility managers, maintenance departments, and commercial buyers with GE HID ballast replacement identification, project quoting, and volume order support.

For volume pricing, availability, or help confirming the correct GE F-Can replacement ballast, contact ADL Supply at 1-800-235-3489.

Reviews