Product Overview

The Sylvania Quicktronic® High Efficiency 49853 (QHE4X32T8UNVISN-SC) Ballast is a commercial-grade, multi-voltage electronic control gear module engineered to operate three or four standard or energy-saving T8 linear and U-bend fluorescent lamps. Outfitted with a universal voltage framework auto-sensing 120–277V input lines, this NEMA Premium certified ballast utilizes an efficient Instant Start initialization layout to secure a normal 0.88 ballast factor profile. Featuring patented Lamp Striation Control (LSC) circuitry to eliminate light shimmering in low-temperature zones, its compact small can (SC) housing serves as the premier energy-saving maintenance choice for commercial office troffers, industrial high-bays, and institutional modular grids.
|
Lamp Loading
3 or 4
T8 Parallel Tracking
|
Input Voltage
120–277V
50/60Hz Universal
|
Ballast Factor
0.88
Normal Light Factor
|
Starting Method
Instant
Requires Shunted
|
Starting Temp
-20°F
Cold Weather Rated
|
ADL Supply Expert Application & Replacement Guide
The Sylvania QHE4X32T8UNV electronic ballast is a high-efficiency facility baseline specified heavily for mass multi-lamp ceiling troffers across commercial commercial spaces, educational institutions, retail centers, and warehouse properties. Featuring an advanced solid-state parallel wiring design, this module delivers full continuous light output across your remain paths; if an individual fluorescent bulb burns out, the remaining lamps stay safely lit to minimize immediate maintenance urgency. This NEMA Premium rated component optimizes line efficiency by 6% over standard electronic ballasts, helping commercial accounts satisfy utility rebate thresholds.
Critical Shunted Sockets Requirement and Multi-Volt Circuit Current Sizing: Property crews executing building maintenance rounds must audit fixture wiring rules before completing installation: this Instant Start device strictly mandates the use of shunted lampholders at all socket connection nodes. Shunted sockets possess an internal copper bridge linking the contact paths together, providing a single path for the high-voltage starting current to strike the gaseous columns instantly.
Connecting an Instant Start module into un-shunted sockets will isolate the line output, accelerating terminal pin degradation, socket charring, or early transistor circuit board failure. Operating a full load of four 32W T8 tubes draws a continuous current loop of 0.93 Amperes under a 120V line or 0.40 Amperes when tied into 277V utility distributions. Ensure your building electrical tracks accommodate the total collective electrical draw of your fixture rows.
|
Verify Before Installing
Shunted Lampholders Mandatory — Parallel Circuit Loading Checks — Small Can (SC) Footprint
Please pull your lighting pan down and confirm the lampholders are internally shunted prior to splicing lead wires. This model features integrated Lamp Striation Control (LSC) circuitry which minimizes the visual swirling or "snaking" light pulses common when running low-wattage energy-saving tubes in uninsulated storage bays down to cold thresholds. The small-can chassis dimensions measure precisely 9.47"L x 1.69"W x 1.18"H.
Mercury and Waste Compliance Notice: This product is a solid-state electronic component and contains 0.0 mg of mercury. It is completely exempt from regional fluorescent transport laws and can be legally shipped to all 50 states. Standard commercial electronic waste (e-waste) handling guidelines apply at end-of-life cycles. |
Detailed Product Specifications
- Brand Name: Sylvania Quicktronic® (OSRAM Sylvania Group / Ledvance Division)
- Product Series Line: Quicktronic® High Efficiency (QHE) Professional NEMA Premium Series
- Sylvania Factory Product Order Code SKU: 49853 (Direct catalog replacement for retired code 49857)
- Manufacturer Description Nomenclature Model: QHE4X32T8UNVISN-SC
- UPC Barcode Number (GTIN-12): 046135498537
- Core Technology Class: High-Frequency Solid-State Electronic Ballast
- Starting Method Classification: Instant Start (Eliminates cathode preheating wear cycles)
- Lamp Wiring Selection Architecture: Parallel Circuit Operation (Lamps function independently)
- Certified Target System Loading: Supports 3-Lamp or 4-Lamp system load arrays
- Nominal Operational Input Voltage: 120V to 277V AC Auto-Sensing Branch Line
- Continuous Input Voltage Security Range: 108V Minimum to 305V Maximum Branch Line Tolerances
- Line Current Frequency Threshold: 50 / 60 Hz
- Total Harmonic Distortion (THD) Limit: Less than 10% under full load (Commercial Architectural Class Protection)
- Power Factor Correction Level: Active Correction Network (Greater than 0.98)
- Audible Component Sound Rating: Class A (Whisper Quiet Industry Standard; 20–24 decibels baseline)
- Minimum Operating Starting Temperature: -20°F (-29°C Cold Weather Striking Cap)
- Maximum Case Temperature Rating (Tc): 158°F (70°C Surface Safety Cutout Threshold)
- Systemic Ballast Factor (BF): 0.88 Normal Ballast Factor Performance Class
- High-Frequency Signal Output: Operating window exceeding 42 kHz (Blocks infrared sensor interference)
- Chassis Enclosure Blueprint Type: Small Can (SC) steel housing with slotted mounting flanges
- Compliance Certifications: NEMA Premium Certified, UL Listed Class P, Type 1 Outdoor, CSA Certified, FCC Part 18 Non-Consumer Class A, RoHS Compliant, Lead-Free Manufacturing Solder Process
Certified System Load Matrix (Lamping Matrix)
This multi-lamp controller is fully certified to strike and manage the following tube configurations safely. Do not mix linear profiles or differing wattages on the same ballast terminal line:
- (3 or 4 Lamps) F32T8: Standard 32W 4-foot linear fluorescent lamps
- (3 or 4 Lamps) F32T8/SUPERSAVER®: Energy-saving reduced-wattage T8 tubes (including 30W, 28W, and 25W variations)
- (3 or 4 Lamps) T8 U-Bend: Standard 32W U-shaped lamps (including FBO32, FBO31, FBO24, FBO16 lines)
- (3 or 4 Lamps) Linear Alternates: Standard FO17 (2-foot), FO25 (3-foot), and FO40 (5-foot) tracks
Operation, Safety & Mounting Compliance
High-Frequency Electronic Signal Transformation
This electronic assembly converts raw alternating current into high-frequency ballast outputs exceeding 42 kHz, completely eliminating stroboscopic workplace eye fatigue and structural flickering loops common in old low-frequency magnetic systems. It incorporates an automated active surge insulation barrier that blocks standard utility switching transients and operational spikes from breaking down sensitive internal solid-state board capacitors, meeting strict ANSI C62.41 transient protections.
Chassis Physical Structural Footprint Dimensions
- Maximum Overall Length (MOL): 9.47" Inches (240.5mm actual bracket footprint length)
- Chassis Housing Body Length: 8.90" Inches (226.1mm actual shell length)
- Chassis Housing Section Width: 1.69" Inches (42.9mm actual track width)
- Chassis Total Housing Height: 1.18" Inches (30.0mm actual vertical thickness)
- Maximum Remote Mounting Field Distance: Up to 20 feet away from fixture lampholders using 18AWG solid copper lines
Commercial Control Gear Equipment Cross-References
This universal multi-volt high-efficiency instant start ballast serves as a direct drop-in replacement or alternative for the following industry models:
- Philips Advance Match: Optanium IOP-4P32-N / Universal 120-277V T8 Instant Start Casing
- GE Lighting Alternative: UltraMax GE432MV-N / High-Efficiency T8 Electronic Control Gear
- Universal Lighting Match: BHP432PUNV-N / Professional Line Multi-Volt Electronic Module
- Keystone Reference alternative: KTEB-432RIS-1-TP / High-Efficiency Instant Start Track Block
- Hatch Reference alternative: HL432IS/UV/N Series Multi-Lamp Core Gear
- Robertson Reference alternative: ISV432MVN / High Power Factor Commercial Series
Bulk Commercial Lighting Supply & Project Support
ADL Supply handles volume distribution shipments, multi-pack logistics, and contractor project quotes for procurement teams, schools, and warehouse facilities nationwide.
For specialized contractor pricing tiers, job-site pallet deliveries, or comprehensive submittal documentation, contact our support team directly at 1-800-235-3489. We are your commercial supply partners as an authorized wholesale Lighting Distributor In Doral, Florida.