Product Overview
![]()
OSRAM FDS/DZE 64642 HLX Xenophot Lamp — 150W | 24V Low Voltage | 5,000 Lumens | GY9.5 Prefocus Bi-Pin Base
The Osram Display/Optic 64642 HLX (FDS/DZE) Lamp is a professional-grade, high-intensity low-voltage tungsten halogen capsule engineered for clinical medical microscopes, slide projection equipment, overhead microfilm readers, architectural showcase spots, and high-fidelity machine vision tracks. Producing a brilliant 5,000 initial lumens of crisp 3400K photographic white light, this compact T4 bulb features an advanced ANSI FDS/DZE specification code tracking profile and utilizes an upgraded Xenophot (HLX) fill gas mix with a precision-coiled axial filament to achieve a flawless color rendering index of 100 CRI. Outfitted with a heavy-duty GY9.5 prefocus bi-pin base and a high-purity clear quartz envelope, it ensures perfect optical focal alignment across its 100-hour calibrated service life.
|
Wattage / Line
150W / 24V
Low-Voltage Required
|
Color Temp
3400K
100 CRI Photo White
|
Brightness
5,000 lm
Xenophot Flux Output
|
ANSI / LIF
FDS / A1/262
GY9.5 Base Sync
|
ADL Supply Expert Application & Replacement Guide
The Osram 64642 HLX flanged halogen capsule is an established industry photo-optic baseline specified universally across clinical diagnostics equipment, surgical operating projectors, high-magnification laboratory instruments, automated quality-control scanning tracks, and architectural profile spots. Utilizing high-density Xenophot technology—where premium xenon gas replaces standard krypton to elevate internal chamber pressure parameters—this bulb forces its axial tungsten filament to burn hotter, producing a raw, high-intensity "Photographic White" beam. This enables lighting designers and laboratory technicians to secure an absolute continuous full-spectrum projection layout, rendering accurate details without creating frequency gaps.
Critical 24V Step-Down Circuit Parameters and Mechanical GY9.5 Seating Controls: Field technicians and commercial contractors executing routine equipment repairs must verify system voltage parameters closely prior to checkout: this capsule runs natively on low-voltage 24V lines and requires a compatible step-down magnetic transformer or electronic power supply to operate. Connecting or bridging this 24V bulb across standard 120V or 277V mainline building grids will trigger immediate high-amperage over-drive failure, causing instant filament blowout or explosive quartz capsule fracturing.
Furthermore, the specialized GY9.5 base features a keyed bi-pin prefocus spacing dimension set at exactly 9.5mm center-to-center. Installers must slide the pins firmly into the fixture receiver slots until the capsule base sits completely flush against the seating collar. This precise mechanical placement aligns the filament core exactly along the fixture reflector's optical center, maximizing center-beam candlepower (CBCP) and preventing optical focus drift.
|
Verify Before Installing
Strict s90 Burn Position — Tempered Enclosed Fixture Mandatory — 100% Mercury-Free Exemption
This bulb tracks a strict s90 burning orientation restriction, requiring vertical operation with the base pointing downward within a ±90-degree allowed tilt variance. Operating outside this structural boundary prompts catastrophic filament sag and premature seal breakdown. Measures exactly 57.2mm (2.25" Inches) in Maximum Overall Length (MOL) with a Light Center Length (LCL) of 31.7mm ($1.25\text{ Inches}$). Never handle the raw quartz bulb barehanded; body oils decompose under high operating temperatures, etching into the quartz glass to trigger localized hot spots that cause immediate capsule fracturing. Clean with an alcohol wipe if contact occurs.
Mercury Compliance and Shipping Notice: This product is a filament-based tungsten halogen thermal capsule and contains 0.0 mg of mercury. It is completely exempt from regional state hazardous substance shipping bans and can be legally sold and shipped to all 50 states (including California, Vermont, and Oregon). |
Detailed Product Specifications
- Brand Name: OSRAM (OSRAM Display/Optic Specialty Lighting Division)
- Product Series Line: Xenophot® (HLX) Low-Voltage Photo-Optic Halogen Series
- Osram Factory Product Order Code SKU: 64642 HLX
- Official Industry ANSI Equipment Code: FDS / DZE
- Official International LIF Specification Code: A1/262
- UPC Barcode / Product Code (EAN-13): 4008321099648
- Core Technology Class: Thermal Incandescent — High-Temperature Xenon-Filled Tungsten Halogen Capsule
- Primary Control Requirement: 24V Step-Down Magnetic Transformer or Regulated Electronic Power Supply
- Operational Power Draw: 150 Watts
- Nominal Operating System Voltage: 24 Volts AC/DC Low-Voltage Circuit Baseline
- Initial Luminous Brightness: 5,000 Lumens (Post standard laboratory seasoning burn)
- Color Temperature Configuration: 3400K Photographic White (Clear High-Purity Quartz Glass Enclosure)
- Color Rendering Index (CRI): 100 Ra (Flawless Continuous Full-Spectrum Energy Distribution)
- Base Type Configuration: GY9.5 Bi-Pin Prefocus Base (Precision 9.5mm prong spacing center-to-center)
- Maximum Bulb Wall Operating Temperature: 900°C (1652°F Outer Chamber Heat Limit)
- Maximum Lead Pin Junction Temperature: 350°C (662°F Maximum Safe End-Seal Thermal Threshold)
- Bulb Shape Enclosure Code: T4 Enclosure (15.0mm / 0.59" Inch actual quartz envelope width)
- Maximum Overall Length (MOL): 57.2mm / 2.25" Inches Structural Body Height Base-to-Tip
- Light Center Length (LCL Dimension): 31.7mm / 1.25" Inches Precision Focal Height Axis Center
- Filament Type Geometry Class: Flat Plane Axial Grid Tungsten Filament Profile
- Rated Average Service Lifespan: 100 Hours (Calibrated high-intensity technical threshold baseline)
- Chassis Burn Position Limit: Strict Vertical Orientation — s90 Position (Vertical base-down & horizontal ±90° allowed tilt)
- Fixture Safety Rating: Suitably Enclosed Halogen Luminaires Only Mandatory (Strict fragmentation containment control)
- Manufacturing Craftsmanship Location: Premium Quality Certified Craftsmanship Made in Germany
Operation, Safety & Mounting Compliance
High-Temperature Regenerative Halogen Halide Cycle Controls
This halogen lamp operates via an internal chemical loop where vaporized tungsten particles bond with halogen gas molecules inside the heated chamber. This compound cycles back onto the burning filament tracks, redepositing the tungsten to preserve filament mass. For this cycle to work cleanly and prevent wall-blackening, the inner envelope must continuously transcend a high temperature threshold exceeding 250°C, making proper convective venting inside showcase track fixtures or medical instrument shrouds mandatory.
Commercial Equipment Industry Cross-References
This standard 150W 24V GY9.5 halogen bulb serves as a direct drop-in replacement or alternative for the following lines:
- Sylvania Alternative Match: 150W 24V GY9.5 Clear T4 Projector Lamp / SKU Code 54112
- Philips Lighting Match: Focusline 150W 24V GY9.5 / Technical Reference Code 7158XHP
- GE Lighting Alternative: 150W 24V GY9.5 Projection Bulb / Trade Part Catalog 97514
Bulk Commercial Lighting Supply & Project Support
ADL Supply delivers commercial-volume logistical fulfillment, tiered commercial contractor discounting strategies, and full pallet project quoting options to electrical accounts across the United States.
For formal wholesale inquiries, volume pricing modifications, or manufacturer spec sheet documentation, reach our commercial branch directly at 1-800-235-3489. We are your commercial supply partners as an authorized wholesale Lighting Distributor In Doral, Florida.