Product Overview

Philips Advance Centium ICN-2S24-T (ICN2S24T35I) Programmed-Start T5HO Ballast | 120-277V | (1-2) F24T5/HO
The Philips Advance Centium ICN-2S24-T (ICN2S24T35I) is a programmed-start electronic ballast that operates one or two F24T5/HO lamps on any supply voltage from 120V to 277V. Programmed-start circuitry preheats the lamp electrodes before ignition, which helps extend lamp life on circuits that switch often, such as occupancy-sensor and daylight-harvesting controls. It also runs one F39T5/HO lamp and a range of 4-pin long compact and circline lamps.
|
Voltage
120–277V
IntelliVolt
|
Starting
Programmed
Start
|
Lamps
1–2
F24T5/HO
|
Ballast Factor
1.00–1.02
F24T5/HO
|
Protection
EOL
+ Auto-Restrike
|
Technical Specifications
| Brand / family | Philips Advance Centium |
| Catalog number | ICN-2S24-T (ICN2S24T35I) |
| Ballast type | Electronic fluorescent, programmed start |
| Input voltage | 120–277V IntelliVolt, 50/60 Hz |
| Lamps per ballast | 1 or 2 (F24T5/HO); 1 (F39T5/HO) |
| Operating frequency | 42–52 kHz |
| Power factor | Greater than 0.98 (primary lamps) |
| Total harmonic distortion | 10% max. on primary lamps; see table for lamp-specific values |
| Lamp current crest factor | 1.7 or less |
| Sound rating | Class A |
| Lamp protection | End-of-life (EOL) protection and auto-restrike |
| Minimum starting temperature | 0°F (-18°C) |
| Case dimensions | 16.70 in L (16.34 in mounting) × 1.18 in W × 1.00 in H |
| Wiring diagram | 73 (1 lamp) / 74 or 74A (2 lamps) |
Electrical Data by Lamp Type
| Lamp configuration | Input power (W) | Ballast factor | Max. THD % | Line current (A) |
|---|---|---|---|---|
| 1 × F24T5/HO | 27 | 1.02 | 10 | 0.23–0.10 |
| 2 × F24T5/HO | 52 | 1.00 | 10 | 0.44–0.19 |
| 1 × F39T5/HO | 40 | 0.90 | 10 | 0.34–0.15 |
| 1 × FT24W/2G11 | 27 | 1.02 | 10 | 0.23–0.10 |
| 2 × FT24W/2G11 | 52 | 1.00 | 10 | 0.44–0.19 |
| 1 × FT36W/2G11 | 34 | 0.90 | 10 | 0.29–0.13 |
| 1 × FC9T5 (22W circline) | 27 | 1.02 | 10 | 0.23–0.10 |
| 2 × FC9T5 (22W circline) | 52 | 1.00 | 10 | 0.44–0.19 |
| 1 × FC12T5 (40W circline) | 40 | 0.84 | 10 | 0.34–0.15 |
Input power, ballast factor, THD and line current are the figures published by Philips Advance for 120–277V operation; ranges in power and current reflect the 120V–277V input range.
Product Overview
The ICN-2S24-T is a 24W-class Centium T5HO ballast: it drives one or two F24T5/HO lamps, a single F39T5/HO lamp, and the 4-pin long compact and circline lamps shown in the compatibility list. It is a low-profile, 16.70-inch ballast. Programmed-start operation, end-of-life protection and auto-restrike are built in, so a replaced lamp restarts without a power reset and a failed lamp is shut down safely.
- Programmed start: preheats the lamp electrodes before ignition, which can extend lamp life in applications with frequent switching, such as occupancy sensors, motion detectors and daylight harvesting.
- IntelliVolt multi-voltage input: one ballast operates on any supply voltage from 120V through 277V (50/60 Hz), which simplifies ordering and installation.
- Auto-restrike: restarts lamps after a lamp is replaced without having to reset power.
- Lamp end-of-life (EOL) protection: safely removes power from a lamp when it fails.
- High-frequency operation (42–52 kHz): designed to avoid interference with infrared devices and anti-theft systems and to eliminate visible flicker.
- Energy-saving lamp compatible: Philips Advance T5HO ballasts are compatible with energy-saving lamps.
Compatible Lamps and Applications
This ballast is rated to operate:
- 1 or 2 × F24T5/HO (24W)
- 1 × F39T5/HO (39W)
- 1 or 2 × FT24W/2G11 (24/27W 4-pin; PL-L24W, F27BX/RS, FT24DL)
- 1 × FT36W/2G11 (36/39W 4-pin; PL-L36W, F39BX/RS, FT36DL)
- 1 or 2 × FC9T5 (22W circline)
- 1 × FC12T5 (40W circline)
Typical applications: Retail, commercial, institutional and industrial lighting, including warehouses, manufacturing areas, schools, offices, and specialty and department stores.
Before Ordering
- Confirm the lamp type and lamp count match the table above. This ballast runs only one F39T5/HO lamp; if you need two F39T5/HO lamps on one ballast, ask us about catalog number ICN-2S39.
- Check your supply voltage is between 120V and 277V (50/60 Hz).
- Compare the case size (16.70 in L x 1.18 in W x 1.00 in H) with the space in your fixture.
- Many customers know this ballast by its Grainger item number or by the full order code ICN2S24T35I; either can be used to confirm you are matching the right part.
Safety and Handling
- Turn off power at the breaker before installing or servicing the ballast, and have the installation done by a qualified electrician in accordance with local electrical codes.
- Wire the ballast exactly as shown on its label and in the wiring diagram; ballast leads are color-coded per ANSI C82.11.
- For one-lamp operation, do not connect the yellow leads (wiring diagram 73).
- Ground the ballast case to the fixture.
- Use only the lamp types and lamp counts listed for this ballast, and remove a failed lamp promptly.
Compliance
- UL Listed, Class P, Type 1 Outdoor; CSA certified where applicable
- Contains no PCBs
- Class A sound rating
- Complies with ANSI C62.41 Category A transient protection and with ANSI C82.11 where applicable
- Complies with FCC 47 CFR Part 18, Non-Consumer (Class A), for conducted and radiated EMI/RFI
- UL Type CC rated
- Manufactured in an ISO 9002-certified factory
Ordering Information
| ADL SKU | PADBICN-2S24 |
| Catalog number | ICN-2S24-T |
| Order code | ICN2S24T35I |
| Brand | Philips Advance |
Cross-reference: Grainger item 3CE44 (ICN-2S24-T).
Questions about compatibility, lamp configurations or replacements? Call ADL Supply at 1-800-235-3489 and we will help you match the right ballast to your fixture.