Philips Advance IMH-100-D-BLS

(No reviews yet) Write a Review
Was: $103.57
Now: $91.37
SKU:
IMH100DBLSM
UPC:
781087032213
Condition:
New
Availability:
IN STOCK
Shipping:
Calculated at Checkout
HS Tariff code:
8504.10.0000

Product Overview

Official Philips Advance Electronics Logo - ADL Supply

The Philips Advance e-Vision® IMH100DBLSM Ballast is a commercial-grade, low-frequency electronic HID ballast engineered to drive a single 100-watt metal halide or ceramic metal halide lamp. Operating on a flexible IntelliVolt 120V to 277V input window, this high-performance module delivers a steady square-wave output to prevent acoustic resonance inside quartz or ceramic arc tubes, maximizing lamp color stability and lamp life. Built with an advanced BLSM configuration featuring bottom-exit leads and integrated mounting studs, it serves as an ideal choice for high-end recessed downlights, commercial retail track fixtures, and architectural showcases.

Load Wattage
100W
(1) HID Lamp
Input Voltage
120-277V
IntelliVolt Auto
Chassis Style
BLSM
Bottom Exit Studs
Output Wave
Low Freq
Square-Wave
THD / PF
< 15%
> 0.90 High PF

ADL Supply Expert Application & Replacement Guide

The Philips Advance e-Vision IMH100DBLSM ballast is a top-tier architectural tracking option specified heavily for retail department displays, commercial office downward lighting, hotel lobbies, and institutional galleries. Engineered to maximize system energy savings relative to obsolete magnetic core-and-coil options, its low-frequency operation runs at less than 200 Hz to entirely stamp out acoustic resonance loops inside modern ceramic burner envelopes, avoiding visible arc flickering and stabilizing color temperature control across extended lifecycles.

Critical Bottom-Exit Geometry and Intelligent End-of-Life Protective Boundaries: Maintenance crews and fixture designers must track the physical **BLSM suffix classification**. This designation dictates that all 9-inch solid copper wire color leads exit exclusively from the flat bottom faceplate of the metal case, working alongside pre-welded, structural mounting studs. This design is purpose-built for mounting flush against recessed plaster rings or deep canopy junction box trays where standard side-exit wiring tabs cannot clear the enclosure walls.

Furthermore, this digital ballast incorporates high-performance automatic End-of-Life (EOL) detection and shutdown safety logic. If a metal halide lamp begins to age non-passively, cycle continuously, or behave erratically under thermal stress, the microprocessor cuts current delivery paths to the lampholder pins after 20 minutes. This safety cutoff prevents localized fixture socket charred faults or ballast coil warping stress. Following a shutdown trip or lamp replacement routine, installers must cycle main breaker line power off, then back on, to reset the internal strike cycle memory.

Verify Before Ordering
4 kV Ignition Pulse Strike Hazards — G53 vs. Screw Base Wire Routing
This electronic HID ballast generates a high-voltage starter ignition pulse peaking up to 4,000V (4 kV) during striking phases. To prevent high-pot voltage grounding out through the fixture frame, ensure all 18 AWG stranded wiring channels are kept free of micro-abrasions, maintaining a maximum remote distance to the lamp-holder socket of 5 feet. When retrofitting standard Edison screw-base fixtures, always attach the red output lead wire directly to the socket's center terminal tab. This alignment forces line energy down the center button pin while routing the neutral blue path safely around the threaded outer metal shell ring, protecting maintenance technicians from high-voltage shock tracking.

Detailed Product Specifications

  • Brand: Philips Advance (e-Vision® Series Professional Grade)
  • Product Series Line: Low-Frequency Fixed-Output Electronic HID Ballasts
  • Philips 12-Digit Factory Catalog ID Suffix: IMH100DBLSM (IMH-100-D-BLSM)
  • Voss / Distribution Part Identifier Number: 03221 / ADVIMH100DBLS
  • UPC Barcode Number (GTIN-12): 781087032213
  • Control Component Class: Electronic HID Pulse Start — Low-Frequency Square Wave [< 200 Hz]
  • Load Circuit Capacity: Operates Exactly (1) 100-Watt HID Metal Halide Lamp
  • Nominal Input Voltage Parameter: IntelliVolt 120V - 277V AC Auto-Sensing Base
  • Line Frequency Range: 50 / 60 Hz
  • Ballast Factor Rating Constant: 1.00 (Standard Optimal Output Regulation)
  • Total Harmonic Distortion (THD): Less than 15% (High Efficiency Tracking Curve)
  • Power Factor Metric: Greater than 0.90 (High-Power Factor Performance)
  • Lamp Crest Factor Capability: Less than 1.5
  • Maximum Lead-Wire Remote Distance Limit: 5 Feet maximum tracking spacing
  • Sound Insulation Class: Sound Rated A (Optimal for Quiet Commercial Environments)
  • Housing Material Enclosure: Heavy-Duty Metal "D" Case (Superior Convective Dissipation)
  • Chassis Wire Integration: 18 AWG Stranded Copper Bottom-Exit Leads
  • Maximum Case Temperature Rating: 194°F (90°C)
  • Minimum Ambient Starting Threshold: -4°F (-20°C)
  • Chassis Physical Length: 5.00" Inches (127.0mm actual base dimension)
  • Chassis Physical Width: 3.00" Inches (76.2mm actual base dimension)
  • Chassis Physical Height: 1.50" Inches (38.1mm actual depth dimension)
  • Industry Compliance Matrix: UL Listed (Type 1 Outdoor), CSA Certified, RoHS Compliant, FCC Non-Consumer

Certified ANSI Metal Halide Load Code Compatibility

This 100W e-Vision engine is calibrated to strike and regulate the following ANSI standard HID fields:

  • ANSI M90 / C90 Circuit Codes: Standard and Ceramic Metal Halide 100W Loads
  • ANSI M140 Circuit Code: Pulse Start Protected 100W Metal Halide Lines
  • ANSI C191 Circuit Code: Specialized Ceramic 100W Commercial Arc Paths

Operation, Safety & Mounting Compliance

High-Frequency Arc Wave Isolation and Thermal Shutoff Safeguards

By driving HID lamps at an engineered square-wave frequency under 200 Hz, this electronic ballast prevents acoustic resonance waveforms from forming inside fragile ceramic arc chambers. Acoustic resonance destabilizes the burning plasma arc, causing catastrophic color shifting, lamp flickering, and micro-fracturing of the internal tube. This ballast incorporates internal automated thermal reset safeguards that cut power if local enclosure temperatures surge past safe boundaries, shielding structural suspended ceiling frames from thermal damage.

Lead-Wire Termination and Proper Grounding Protocols

During track line or recessed can retrofits, installers must secure the integrated 8-32 thread mounting studs tightly to the fixture chassis tray to anchor an unbroken grounding path. Do not route the red (center pin contact) or blue (outer shell contact) output lead lines adjacent to municipal neutral or grounding tracks, as high potential pulse spikes will trigger line transformer faults. Use only porcelain-insulated high-pot rated lampholder sockets to ensure continuous dielectric separation over long-term operations.

Commercial Equipment Industry Cross-References

This IMH100DBLSM bottom-exit electronic HID control module serves as a substitute for the following setups:

  • Alternative Wiring Layout Cross: IMH100DLFM (Identical "D" case electrical engine with Side-Exit Lead layout)
  • Sylvania Quicktronic Match: QTP 1x100MH/UNV-J (Order Code 51915 — *Note: Verify lead exit vectors*)
  • Metrolight Alternative: SmartElectronic 100W Low Frequency HID Control Gear

Bulk Commercial Lighting Supply & Project Support

ADL Supply handles volume logistics management, tiered commercial contractor pricing models, and full pallet project quotes for facility teams, municipal procurement agents, and electrical accounts nationwide.

For professional contractor tiered discounts, full pallet freight distributions, or dedicated technical submittal specification sheets, reach our support center directly at 1-800-235-3489. We are your commercial supply partners as an authorized wholesale Lighting Distributor In Doral, Florida.

Reviews