Philips Advance Rovr IDA-128-D (1) F28T5 Ballast

(No reviews yet) Write a Review
Was: $98.44
Now: $86.55
SKU:
ADV- IDA128D35M
UPC:
Condition:
New
Availability:
In Stock
Shipping:
Calculated at Checkout
HS Tariff code:
8504.10.0000

Product Overview

Philips Advance Logo

Philips Advance ROVR IDA-128-D — 1-Lamp T5 DALI Electronic Dimming Ballast, 120-277V, Programmed Start

The Philips Advance ROVR IDA-128-D is a 1-lamp T5 DALI electronic dimming ballast from Philips Advance, designed for precision dimming control in commercial T5 fluorescent lighting systems. Universal voltage input covers 120–277V ±10% at 50/60Hz. Programmed rapid start, DALI protocol control, ballast factor range 0.03–1.00 (dimming range 100% to 3%), THD under 10%, power factor greater than 0.98 at full output, output frequency above 42kHz, EOL lamp protection, auto-restart circuitry, Class A sound rating, and UL Listed Class P / Type 1 Outdoor. Five-year warranty. ISO 9001 manufactured. Verify lamp type, input voltage, and DALI control compatibility before ordering.

Lamp Count
1 Lamp
T5 Fluorescent
Input Voltage
120–277V
±10% Universal
Dimming
DALI
100% to 3%
Start Type
Programmed
Rapid Start
Min Start Temp
50°F
10°C

Technical Specifications

Brand Philips Advance — ROVR
Model IDA-128-D
Ballast Type Electronic Dimming — DALI Protocol
Lamp Count 1 Lamp
Compatible Lamp Types F14T5, F21T5, F28T5, F28T5/ES (25W)
Input Voltage 120–277V AC (±10%, 50/60Hz)
Start Method Programmed Rapid Start
Lamp Connection Series
Dimming Protocol DALI (Class 1 or Class 2 circuit)
Ballast Factor Range 0.03 – 1.00 (100% to 3% light output)
Power Factor >0.98 at full output; >0.90 throughout dimming range
Total Harmonic Distortion (THD) <10%
Output Frequency >42kHz (eliminates flicker; IR device compatible)
Lamp Current Crest Factor 1.7 (max)
Sound Rating Class A
Minimum Starting Temperature 50°F (10°C)
Maximum Case Temperature 70°C
EOL Protection Yes — lamp end-of-life detection for T5 and CFL lamps
Auto-Restart Yes — restarts lamps without resetting power
Control Lead Protection Yes — defaults to maximum output if control leads connected to mains
PCB Content No PCB
Dimensions 16.70" L x 1.18" W x 1.00" H
Warranty 5 years from date of manufacture
Listings / Compliance UL Listed Class P, UL Type 1 Outdoor, CSA Certified, FCC 47 CFR Part 18 (Non-Consumer), ANSI C82.11, ANSI C62.41 Cat. A, NEMA 410, ISO 9001

Compatible Lamps

F14T5 14W — Input 6–19W — BF 0.03–1.00
F21T5 21W — Input 6–25W — BF 0.03–1.00
F28T5 28W — Input 7–32W — BF 0.03–1.00
F28T5/ES (25W) 25W — Input 7–30W — BF 0.03–1.00

Product Overview

The Philips Advance ROVR IDA-128-D is a specification-grade DALI dimming ballast engineered for 1-lamp T5 fluorescent systems in commercial and institutional facilities where automated lighting control, daylight harvesting, or occupancy-based dimming is required. DALI (Digital Addressable Lighting Interface) protocol allows individual ballast addressability on a shared control bus — enabling zone control, scene setting, and integration with building automation systems without dedicated control wiring to each fixture.

Programmed rapid start preheats lamp cathodes before striking the arc, maximizing lamp life in high-cycling DALI-controlled environments. Output frequency above 42kHz eliminates visible flicker at all dimming levels and prevents interference with infrared remote control systems. Control lead protection circuitry prevents accidental connection of DALI leads to mains voltage — defaulting to maximum output rather than ballast failure. Auto-restart circuitry restores operation after a transient interruption without requiring a manual power cycle.

Compatible Applications

  • DALI-controlled commercial lighting systems — Individual ballast addressing on shared DALI bus for zone control, scene management, and building automation integration.
  • Daylight harvesting — Integrates with photosensor-based DALI controllers to reduce electric light output proportionally to available daylight.
  • Occupancy sensor systems — Programmed start protects lamp life in high-switching occupancy-controlled applications.
  • Outdoor and low-temperature applications — UL Type 1 Outdoor rated; 50°F minimum start temperature for covered outdoor installations.
  • AV and IR-sensitive environments — >42kHz output frequency prevents interference with infrared devices.

Before Ordering — Verify

  • Lamp Type: Confirm your lamp is F14T5, F21T5, F28T5, or F28T5/ES (25W).
  • Lamp Count: This is a 1-lamp ballast. For 2-lamp applications, see Philips Advance IDA-2S28-D.
  • Input Voltage: Confirm your circuit voltage is within 120–277V ±10%.
  • Dimming Control: Confirm your control system uses DALI protocol (Class 1 or Class 2 circuit). This ballast is not compatible with 0-10V or phase-cut dimming controls.
  • Physical Fit: Confirm 16.70" x 1.18" x 1.00" dimensions fit within your fixture's ballast cavity.

Cross Reference

  • Sylvania 51356 QTP1x28T5/UNV DALI
  • Universal B128PUNVDV1

Compliance

  • UL Listed Class P, UL Type 1 Outdoor, CSA Certified.
  • FCC 47 CFR Part 18 Non-Consumer (Class A) EMI/RFI compliant.
  • ANSI C82.11, ANSI C62.41 Category A transient protection, NEMA 410.
  • ISO 9001 Quality System certified manufacturing.
  • No PCB content.
  • Five-year warranty from date of manufacture at ≤70°C case temperature.

Ordering Information

  • Brand: Philips Advance — ROVR
  • Model: IDA-128-D
  • Input Voltage: 120–277V
  • Lamp Compatibility: 1-lamp T5 fluorescent (F14T5, F21T5, F28T5, F28T5/ES)
  • Dimming Protocol: DALI
  • Packaging: Sold individually.
  • Case quantities and bulk pricing: Contact ADL Supply for volume orders.

For wholesale pricing, bulk availability, or help confirming the correct replacement ballast, contact ADL Supply at 1-800-235-3489.