Product Overview

GE BWA 2000W 120V SSTV Stage, Studio & Theater Halogen Lamp – ANSI BWA | 3200K | 54,000 Lumens | Mogul Bi-Post
54,000 lumens at 3200K with CRI 100 – the highest-output SSTV halogen lamp on 120V circuits, designed for professional film, broadcast, and large-venue stage lighting.
|
Wattage / Voltage
2000W / 120V
SSTV Halogen
|
ANSI Code
BWA
SSTV Stage
|
Initial Lumens
54,000
lm
|
Color Temp
3200K
Studio White
|
Base Type
Mogul
Bi-Post G38 / GX38
|
Quick Specs
- Brand: GE (General Electric)
- SKU / Order Code: GE-39587
- ANSI Code: BWA
- Lamp Type: SSTV Halogen – Stage, Studio & Theater
- Wattage: 2000W
- Voltage: 120V
- Base Type: Mogul Bi-Post (G38 / GX38)
- Color Temperature: 3200K (Studio White)
- CRI: 100
- Initial Lumens: 54,000 lm
- Filament Type: CC-8 Coiled Coil
- Burn Position: Base Down to Horizontal (not base up)
- Rated Average Life: Verify with manufacturer specification sheet
Product Overview
The GE BWA is a 2000-watt, 120-volt SSTV halogen lamp that delivers 54,000 initial lumens at 3200K studio white with CRI 100. It represents the highest lumen output in the GE Quartzline SSTV halogen platform, making it a professional choice for high-intensity film and broadcast lighting, large-venue stage fixtures, studio production rigs, and photography applications requiring maximum tungsten output on 120V circuits.
With a mogul bi-post base (G38/GX38), this lamp provides secure electrical and mechanical contact for the 16.7A operating current. The CC-8 coiled coil filament creates a compact, intense source appropriate for large-aperture Fresnel and open-face flood luminaires. The 3200K color temperature matches broadcast camera white balance, and CRI 100 ensures full-spectrum color accuracy.
Note on rated life and dimensions: Rated average life, overall length, and bulb diameter are not stated in the available source data. Verify these specifications with the GE product data sheet for SKU GE-39587 / ANSI BWA before ordering.
Why Choose This Product
- 54,000 initial lumens – maximum output 2000W SSTV halogen: Among the highest lumen outputs available from a tungsten halogen source on 120V – ideal for large Fresnel floods, open-face studio fixtures, and high-intensity photoflood applications.
- ANSI BWA – broadcast and production standard: The BWA ANSI code defines exact electrical and photometric parameters, ensuring replacement lamps meet original fixture specifications.
- 3200K studio white – camera-balanced output: Broadcast-standard color temperature for professional video, film, and TV production.
- CRI 100 – full-spectrum halogen accuracy: Continuous-spectrum light output renders all colors perfectly – required for film and broadcast where color accuracy affects post-production grading.
- CC-8 coiled coil filament: Standard high-wattage SSTV filament configuration providing a compact, concentrated source for professional luminaires.
- 120V operation: Operates on standard North American 120V circuits – no step-up transformer required (dedicated high-current circuit needed).
Technical Specifications
| Brand | GE (General Electric) |
| Model | BWA / GE-39587 |
| Lamp Type | SSTV Halogen (Stage, Studio & Theater) |
| Wattage | 2000 W |
| Voltage | 120 V |
| Base | Mogul Bi-Post (G38 / GX38) |
| ANSI Code | BWA |
| Lumens | 54,000 lm |
| Color Temperature | 3200K |
| CRI | 100 |
| Rated Life | Verify with manufacturer specification sheet |
| Filament Type | CC-8 Coiled Coil |
| Burn Position | Base Down to Horizontal (not base up) |
| Operating Current | ~16.7A at 120V |
| Special Features | Quartzline, high-output SSTV, studio white |
Dimensions
| Maximum Overall Length (MOL) | Verify with manufacturer specification sheet |
| Bulb Diameter | Verify with manufacturer specification sheet |
| Bulb Shape | Verify with manufacturer specification sheet |
Applications
- Film and broadcast lighting – high-intensity Fresnel and open-face flood fixtures
- Large-venue stage and theatrical production – fixed and variable-focus flood fixtures
- Professional studio photography and photoflood – high-output continuous tungsten sources
- Television production – studio-grade Fresnel and soft box fixtures requiring 2000W tungsten at 3200K
Compatibility & Replacement
Fixture type: This lamp fits professional stage and studio fixtures designed for a mogul bi-post base (G38/GX38) and 2000W T-type SSTV halogen lamps – typically large Fresnel floods, open-face studio fixtures, and high-intensity photoflood lights.
Base: Mogul Bi-Post (G38/GX38) – physically larger than G9.5 or GY9.5 bases used in lower-wattage stage lamps.
Ballast: No ballast required – operates directly on 120V mains power.
Before ordering, confirm:
- ANSI code – BWA: Verify your fixture specifies ANSI BWA. Not interchangeable with BVT, DPY, or other 2000W SSTV designations.
- Voltage – 120V: Verify fixture and supply circuit are 120V. Do not install in 240V or 208V fixtures.
- Base type – Mogul Bi-Post: Confirm your fixture uses a mogul bi-post lampholder.
- Burn position – base down to horizontal only: Base-up operation is not permitted and may cause premature failure or lamp burst.
- Circuit capacity: A dedicated 20A or higher circuit is required for 2000W / 16.7A continuous draw. Verify wiring and dimmer ratings.
- Rated life and dimensions: Confirm with GE product data sheet for ANSI BWA / SKU GE-39587 before ordering for maintenance planning or fixture clearance.
Ordering Information
- Brand: GE (General Electric)
- SKU / Order Code: GE-39587
- ANSI Code: BWA
- Lamp Type: 2000W 120V SSTV Stage, Studio & Theater Halogen
- Base: Mogul Bi-Post (G38/GX38)
- Case quantities and bulk pricing available – contact ADL Supply for volume orders.
Compliance & Certifications
- Verify UL listing status with manufacturer specification sheet.
- Verify RoHS compliance status with manufacturer specification sheet.
- Verify FDA radiation performance compliance with manufacturer specification sheet.
- Verify Prop 65 warning requirements with manufacturer specification sheet.
ADL Supply recommends confirming all applicable compliance data with the GE official product data sheet (ANSI BWA / SKU GE-39587) prior to specification or installation.
Safety & Handling Notes
- High pressure warning – face shield required: SSTV lamps operate under high internal pressure. Always wear a face shield and protective gloves during handling and installation. Lamp burst can cause serious injury.
- No bare hands: Never touch the bulb envelope with bare skin. Oils cause hot spots leading to premature failure or lamp burst.
- Do not exceed rated voltage: Operating above 120V dramatically shortens lamp life. Verify supply voltage before installing.
- Burn position – base down to horizontal only: Incorrect orientation can cause premature failure or lamp burst.
- Extreme heat and UV output: Use only in approved enclosed luminaires with appropriate UV filtering.
- Allow complete cool-down before handling: Allow lamp to cool completely before relamping.
- Follow your fixture manufacturer’s service documentation for lamp replacement procedures.