Product Overview

GE CSR1500/S/DE P/N 96800 – 1500W/115V Quartz Metal Halide (CSR) SSTV Lamp | 6000K | 132,000 Lumens | SFc 10-4 Double-End
132,000 lumens at 6000K with CRI 82 – a high-output 1500W quartz metal halide CSR lamp for film, broadcast, follow spot, and arena lighting applications.
|
Wattage / Voltage
1500W / 115V
Quartz Metal Halide
|
Initial Lumens
132,000
lm
|
Color Temp
6000K
Daylight
|
CRI
82
Good Color
|
Base Type
Double-End
SFc 10-4 SFc 10-4
|
Quick Specs
- Brand: GE (General Electric)
- SKU / Order Code: CSR1500/S/DE/6000K
- Part Number: 96800
- ANSI Code: Not applicable (CSR series)
- Lamp Type: Quartz Metal Halide (CSR)
- Wattage: 1500 W
- Voltage: 115 V
- Base Type: Double-End SFc 10-4
- Color Temperature: 6000K (Daylight)
- CRI: 82
- Initial Lumens: 132,000 lm
- Rated Average Life: Verify with manufacturer specification sheet
- Maximum Overall Length (MOL): 5.43 in
- Burn Position / Ballast: Compatible with electronic or magnetic ballasts (DC power required)
Product Overview
The GE CSR1500/S/DE is a 1500-watt, 115-volt quartz metal halide (CSR) lamp from the GE SSTV family. It delivers an exceptionally high 132,000 initial lumens at 6000K daylight color temperature with a CRI of 82. This high-intensity discharge (HID) source is designed for professional film, broadcast, follow spot, and large-venue entertainment lighting where extreme output and daylight color balance are required.
The double-ended SFc 10-4 base configuration is common in high-wattage follow spots, searchlights, and arena luminaires. Unlike tungsten halogen lamps, CSR metal halide lamps require a dedicated ballast and DC power supply. The 6000K color temperature matches daylight, making it ideal for outdoor venue lighting and applications where camera white balance is set to daylight (5500K-6000K).
Why Choose This Product
- 132,000 lumens – extremely high output: One of the brightest single-source lamps available for follow spots, searchlights, and large-venue lighting.
- 6000K daylight color temperature: Matches natural daylight and outdoor camera white balance – ideal for arena events, outdoor broadcasts, and daylight-matching applications.
- CRI 82 – good color rendering: Suitable for broadcast and live event production where accurate color discrimination is important.
- CSR quartz metal halide technology: Delivers high efficacy (approx. 88 lumens per watt) compared to tungsten halogen, reducing power consumption and heat for equivalent light output.
- SFc 10-4 double-ended base: Industry-standard for high-wattage follow spot and searchlight lamps.
- Ballast compatibility: Operates with both electronic and magnetic ballasts (DC power required).
Technical Specifications
| Brand | GE (General Electric) |
| Model / Part Number | CSR1500/S/DE / 96800 |
| ANSI Code | Not applicable |
| Lamp Type | Quartz Metal Halide (CSR) |
| Wattage | 1500 W |
| Voltage | 115 V |
| Base | Double-End SFc 10-4 |
| Color Temperature | 6000K (Daylight) |
| CRI | 82 |
| Initial Lumens | 132,000 lm |
| Rated Average Life | Verify with manufacturer specification sheet |
| Ballast Type | Compatible with electronic or magnetic (DC power required) |
Dimensions
| Maximum Overall Length (MOL) | 5.43 in (138 mm) |
| Bulb Diameter | Verify with manufacturer specification sheet |
Applications
- Film and broadcast lighting – high-output daylight sources for exterior and large-studio production
- Stage, studio, and entertainment – follow spots, searchlights, and arena lighting systems
- Follow spot and spotlight systems requiring 1500W CSR metal halide lamps
- Outdoor and arena lighting – concerts, sporting events, large-scale productions
- Theme park and architectural feature lighting
Compatibility & Replacement
Fixture type: This CSR1500/S/DE lamp fits professional follow spots, searchlights, and large-venue luminaires designed for double-ended SFc 10-4 base metal halide lamps. Common in fixtures from Lycian, Strong, Robert Juliat, and other high-output follow spot manufacturers.
Base: Double-End SFc 10-4 – a recessed double-contact base with 10mm spacing. Confirm your fixture uses SFc 10-4 lampholders.
Ballast requirement – CRITICAL: CSR/CSS metal halide lamps require a dedicated ballast and DC power supply. Do not operate on AC mains directly. Verify your fixture includes a compatible electronic or magnetic ballast rated for 1500W metal halide lamps.
Before ordering, confirm:
- Lamp type – CSR1500/S/DE: Verify your fixture specifies this GE CSR lamp or equivalent.
- Voltage – 115V: Verify ballast output matches lamp voltage rating.
- Base type – SFc 10-4: Physically confirm your fixture uses double-ended SFc 10-4 lampholders.
- Ballast compatibility: Ensure your fixture has a working ballast (electronic or magnetic) rated for 1500W quartz metal halide lamps. Incorrect ballast or AC operation will destroy the lamp.
- Physical dimensions: Verify your fixture accepts a lamp with 5.43-inch overall length.
- Rated life: Confirm with GE data sheet for maintenance scheduling.
Ordering Information
- Brand: GE (General Electric)
- Part Number: 96800
- SKU / Order Code: CSR1500/S/DE/6000K
- Lamp Type: 1500W/115V Quartz Metal Halide (CSR) – SFc 10-4 Base, 6000K, 132,000 lm
- Case quantities and bulk pricing available – contact ADL Supply for volume orders.
Compliance & Certifications
- Verify UL / ETL listing status with manufacturer specification sheet.
- Verify RoHS compliance status with manufacturer specification sheet.
- Verify FDA radiation performance compliance (UV filtering requirements) with manufacturer specification sheet.
- Verify Prop 65 warning requirements with manufacturer specification sheet.
ADL Supply recommends confirming all applicable compliance data with the GE official product data sheet (CSR1500/S/DE / P/N 96800) prior to specification or installation.
Safety & Handling Notes
- DC power required – critical: CSR/CSS metal halide lamps require a DC power supply and compatible ballast. Incorrect power supply (AC mains) will destroy the lamp immediately and may cause rupture or fire. Use only with approved ballasts.
- High pressure warning – face shield required: Metal halide lamps operate under very high internal pressure. Always wear a face shield and protective gloves during handling and installation. Lamp burst can cause serious injury.
- No bare hands: Never touch the quartz envelope with bare skin. Oils cause hot spots leading to premature failure or lamp burst. Use clean gloves or a lint-free cloth.
- Do not exceed rated voltage: Operating above rated voltage dramatically shortens lamp life. Verify ballast output before installing.
- Burn position: Observe the rated burn position as specified by your fixture and ballast system. Incorrect orientation can cause premature failure.
- Extreme heat and UV output: These lamps produce intense UV radiation and heat. Use only in approved enclosed luminaires with appropriate UV filtering glass. Never operate with broken outer envelope.
- Allow cool-down: Allow lamp to cool completely before handling or relamping (minimum 10-15 minutes). Do not touch immediately after switching off.
- Follow fixture manufacturer's service documentation for lamp replacement procedures.