Sylvania Lighting Logo

Sylvania 69248 XBO 2500 W OFR – 2500W | 6000K Daylight White | 100,000 Lumens | CRI 98 | 29V DC | 85 AmpsA | OFR

The Sylvania 69248 XBO 2500 W OFR is a 2500W 6000K Daylight White xenon short-arc high-pressure lamp delivering 100,000 initial lumens at CRI 98, 85 AmpsA DC operating current, 29V operating voltage, 2,000-hour rated life, and ozone-free (OFR) designation. SFaX27-13 (Anode), SFaX27-14 (Cathode) anode/cathode base configuration. Carbon arc replacement for large-format cinema projection, high-power searchlights, solar simulation, and large-venue follow spot systems. Item 69248. UPC: 46135692482.


Wattage
2500W
Xenon Arc
DC Voltage
29V
Operating
Lumens
100,000
Initial lm
CRI
98
Full Spectrum
Operating A
85 AmpsA
Current

Quick Specs

  • Brand: Sylvania
  • Item / Catalog Number: 69248
  • UPC / EAN: 46135692482
  • Lamp Type: Xenon Short-Arc High-Pressure (XBO) — Ozone-Free (OFR)
  • Wattage: 2500W
  • Operating Voltage: 29V (DC)
  • Operating Current: 85 AmpsA
  • Color Temperature: 6000K Daylight White
  • CRI: 98
  • Initial Lumens: 100,000 lm
  • Luminous Intensity: 9500cdcd
  • Rated Average Life: 2,000 hours
  • Base Type: SFaX27-13 (Anode), SFaX27-14 (Cathode)
  • Overall Length: 428mm
  • Burn / Operating Position:
  • Gas Fill: Carbon
  • Ozone-Free (OFR): Yes — UV-blocking envelope suppresses ozone-generating 185nm radiation

Product Overview

The Sylvania 69248 XBO 2500 W OFR is a 2500W xenon short-arc high-pressure lamp producing 100,000 lumens at 6000K Daylight White with CRI 98 — a direct current arc source that delivers a compact, extremely bright, daylight-balanced point source appropriate for large-format cinema projection, military searchlights, and high-power follow spot systems. At 85 AmpsA operating current and 29V DC, this lamp requires a dedicated constant-current DC power supply rated for these parameters.

The OFR (Ozone-Free) designation indicates this lamp uses a UV-blocking quartz envelope that suppresses the 185nm radiation responsible for ozone generation — appropriate for enclosed or limited-ventilation installations where ozone accumulation must be controlled. The SFaX27-13 (Anode), SFaX27-14 (Cathode) base provides separate anode and cathode connections; correct DC polarity is essential for lamp operation and safety. Rated life of 2,000 hours varies with operating duty cycle and power supply quality — maintain adequate lamp stock for your production schedule. Burn position: .


Applications

  • Large-format cinema projection – XBO xenon short-arc lamps are the professional standard for commercial cinema projection systems requiring maximum screen luminance. 2500W output is appropriate for large-format cinema projection, military searchlights, and high-power follow spot systems.
  • High-power searchlights and follow spots – Large-venue follow spots, aerial searchlights, and entertainment lighting requiring maximum luminous intensity (100,000 lm / 9500cdcd) at extended distances.
  • Solar simulation and scientific testing – Solar simulators, UV exposure systems, and optical testing equipment requiring stable CRI 98 daylight-spectrum output at defined wattage.
  • âš  High-pressure safety warning — face shield mandatory: XBO lamps operate at extreme internal pressure. Always wear a face shield and heavy protective gloves during all handling and installation operations. Lamp burst risk if improperly handled or dropped.

Handling and Installation Requirements

  • âš  High-pressure — face shield and gloves mandatory: XBO lamps operate at extreme internal pressure. Face shield and heavy protective gloves are required during all handling and installation. Never handle without PPE.
  • DC power supply required — 29V DC / 85 AmpsA: XBO lamps require a dedicated constant-current DC power supply. Do not connect to AC. Verify power supply is rated for 29V DC at 85 AmpsA continuous output.
  • Anode/cathode polarity — SFaX27-13 (Anode), SFaX27-14 (Cathode): Verify correct DC polarity per power supply and fixture documentation. Reversed polarity will damage the lamp and may cause failure.
  • Burn position — : Operate only within the specified burn position range. Incorrect orientation shortens lamp life and may cause failure.
  • Do not touch the lamp envelope: Skin oils cause hot spots that can lead to catastrophic failure under high-pressure operation. Use clean cotton gloves at all times. If touched accidentally, clean with isopropyl alcohol.
  • Ozone-free (OFR) — ventilation still required: This lamp suppresses ozone generation, but adequate ventilation is still required due to extreme heat output and UV emissions.
  • Allow minimum 30-minute cool-down before handling: XBO lamps operate at extreme temperature. Never touch the housing or lamp immediately after switching off.
  • Verify power supply compatibility: Use only power supplies specifically designed and approved for 2500W XBO xenon short-arc lamp operation.

Ordering Information

  • Brand: Sylvania
  • Item / Catalog Number: 69248
  • UPC / EAN: 46135692482
  • Wattage / DC Voltage: 2500W / 29V DC
  • Base: SFaX27-13 (Anode), SFaX27-14 (Cathode)
  • Case quantities and bulk pricing: Contact ADL Supply for volume orders.

Safety and Compliance

  • âš  High-pressure lamp — explosion risk if mishandled. Follow all manufacturer safety guidelines. Protective equipment mandatory during handling.
  • Verify RoHS compliance with manufacturer specification sheet.
  • Verify applicable FDA radiation performance compliance for your application.
  • Verify Prop 65 warning requirements with manufacturer specification sheet.

ADL Supply recommends confirming all specifications with the manufacturer product data sheet prior to specification or installation.

Reviews

(No reviews yet) Write a Review