Product Overview

Sylvania 69256 XBO 2000 W/SHSC OFR – 2000W | 6000K Daylight White | 80,000 Lumens | CRI 98 | 27V DC | 70 AmpsA | OFR
The Sylvania 69256 XBO 2000 W/SHSC OFR is a 2000W 6000K Daylight White xenon short-arc high-pressure lamp delivering 80,000 initial lumens at CRI 98, 70 AmpsA DC operating current, 27V operating voltage, 2,000-hour rated life, and ozone-free (OFR) designation. SK27/50 (Anode), SFcX27-8 (Cathode) anode/cathode base configuration. Carbon arc replacement for large-format cinema projection, high-power searchlights, solar simulation, and large-venue follow spot systems. Item 69256. UPC: 46135692567.
|
Wattage
2000W
Xenon Arc
|
DC Voltage
27V
Operating
|
Lumens
80,000
Initial lm
|
CRI
98
Full Spectrum
|
Operating A
70 AmpsA
Current
|
Quick Specs
- Brand: Sylvania
- Item / Catalog Number: 69256
- UPC / EAN: 46135692567
- Lamp Type: Xenon Short-Arc High-Pressure (XBO) — Ozone-Free (OFR)
- Wattage: 2000W
- Operating Voltage: 27V (DC)
- Operating Current: 70 AmpsA
- Color Temperature: 6000K Daylight White
- CRI: 98
- Initial Lumens: 80,000 lm
- Luminous Intensity: 7500cdcd
- Rated Average Life: 2,000 hours
- Base Type: SK27/50 (Anode), SFcX27-8 (Cathode)
- Overall Length: 236mm
- Burn / Operating Position:
- Gas Fill: Carbon
- Ozone-Free (OFR): Yes — UV-blocking envelope suppresses ozone-generating 185nm radiation
Product Overview
The Sylvania 69256 XBO 2000 W/SHSC OFR is a 2000W xenon short-arc high-pressure lamp producing 80,000 lumens at 6000K Daylight White with CRI 98 — a direct current arc source that delivers a compact, extremely bright, daylight-balanced point source appropriate for large-format cinema projection, military searchlights, and high-power follow spot systems. At 70 AmpsA operating current and 27V DC, this lamp requires a dedicated constant-current DC power supply rated for these parameters.
The OFR (Ozone-Free) designation indicates this lamp uses a UV-blocking quartz envelope that suppresses the 185nm radiation responsible for ozone generation — appropriate for enclosed or limited-ventilation installations where ozone accumulation must be controlled. The SK27/50 (Anode), SFcX27-8 (Cathode) base provides separate anode and cathode connections; correct DC polarity is essential for lamp operation and safety. Rated life of 2,000 hours varies with operating duty cycle and power supply quality — maintain adequate lamp stock for your production schedule. Burn position: .
Applications
- Large-format cinema projection – XBO xenon short-arc lamps are the professional standard for commercial cinema projection systems requiring maximum screen luminance. 2000W output is appropriate for large-format cinema projection, military searchlights, and high-power follow spot systems.
- High-power searchlights and follow spots – Large-venue follow spots, aerial searchlights, and entertainment lighting requiring maximum luminous intensity (80,000 lm / 7500cdcd) at extended distances.
- Solar simulation and scientific testing – Solar simulators, UV exposure systems, and optical testing equipment requiring stable CRI 98 daylight-spectrum output at defined wattage.
- âš High-pressure safety warning — face shield mandatory: XBO lamps operate at extreme internal pressure. Always wear a face shield and heavy protective gloves during all handling and installation operations. Lamp burst risk if improperly handled or dropped.
Handling and Installation Requirements
- âš High-pressure — face shield and gloves mandatory: XBO lamps operate at extreme internal pressure. Face shield and heavy protective gloves are required during all handling and installation. Never handle without PPE.
- DC power supply required — 27V DC / 70 AmpsA: XBO lamps require a dedicated constant-current DC power supply. Do not connect to AC. Verify power supply is rated for 27V DC at 70 AmpsA continuous output.
- Anode/cathode polarity — SK27/50 (Anode), SFcX27-8 (Cathode): Verify correct DC polarity per power supply and fixture documentation. Reversed polarity will damage the lamp and may cause failure.
- Burn position — : Operate only within the specified burn position range. Incorrect orientation shortens lamp life and may cause failure.
- Do not touch the lamp envelope: Skin oils cause hot spots that can lead to catastrophic failure under high-pressure operation. Use clean cotton gloves at all times. If touched accidentally, clean with isopropyl alcohol.
- Ozone-free (OFR) — ventilation still required: This lamp suppresses ozone generation, but adequate ventilation is still required due to extreme heat output and UV emissions.
- Allow minimum 30-minute cool-down before handling: XBO lamps operate at extreme temperature. Never touch the housing or lamp immediately after switching off.
- Verify power supply compatibility: Use only power supplies specifically designed and approved for 2000W XBO xenon short-arc lamp operation.
Ordering Information
- Brand: Sylvania
- Item / Catalog Number: 69256
- UPC / EAN: 46135692567
- Wattage / DC Voltage: 2000W / 27V DC
- Base: SK27/50 (Anode), SFcX27-8 (Cathode)
- Case quantities and bulk pricing: Contact ADL Supply for volume orders.
Safety and Compliance
- âš High-pressure lamp — explosion risk if mishandled. Follow all manufacturer safety guidelines. Protective equipment mandatory during handling.
- Verify RoHS compliance with manufacturer specification sheet.
- Verify applicable FDA radiation performance compliance for your application.
- Verify Prop 65 warning requirements with manufacturer specification sheet.
ADL Supply recommends confirming all specifications with the manufacturer product data sheet prior to specification or installation.