Product Overview
![]()
Universal AccuStart5® Triad B254PUNV-D Electronic Programmed Rapid Start Ballast – 1 or 2 Lamp, 120-277V, Series Wiring
The Universal AccuStart5® Triad B254PUNV-D is a programmed rapid-start electronic ballast wired for series lamp operation, built to drive 1 or 2 lamps from a wide range of T5HO, T8, and 2G11 4-pin compact fluorescent families. It operates on 120-277VAC, +/-10%, 50/60Hz, and can also run on 125VDC input. Active power factor correction and auto-reset end-of-lamp-life shutdown circuitry are built in.
|
Lamp Load
1 or 2
T5HO/T8/2G11
|
Input Voltage
120-277V
AC (+125VDC)
|
Start Type
Prog. Rapid
AccuStart5
|
Circuitry
Series
Lamp Operation
|
Max Case Temp
167°F
75°C
|
Technical Specifications
| Model Number | B254PUNV-D |
| Brand | Universal Lighting Technologies (AccuStart5®, a Triad® brand) |
| Ballast Type | Electronic, programmed rapid start |
| Line Voltage | 120-277VAC, ±10%, 50/60Hz; also operates on 125VDC input, (+)L (-)N |
| Circuit | Series lamp operation |
| Power Factor | >.94 to >.99 depending on lamp type/count/voltage (active PFC) |
| Ballast Factor | 0.86 to 1.20 depending on lamp type/count – see lamp table below (consult lamp manufacturer for applications above 1.20 BF) |
| Total Harmonic Distortion | <10% across all documented configurations |
| Crest Factor | <1.7 |
| Minimum Starting Temperature | 0°F / -18°C standard; -20°F / -29°C with no remote mounting |
| Maximum Case Temperature | 167°F / 75°C |
| Sound Rating | A |
| Remote Mounting | Up to 20 ft.; consult factory for tandem wiring |
| Mounting Length | 16.28" +/-0.010" / 413.5mm (center to center) |
| Overall Length | 16.88" +/-0.010" / 428.8mm |
| Width | 1.245" +0.01"/-0.02" / 31.6mm |
| Height | 1.00" +0.04"/-0.01" / 25.4mm |
| Weight | 1.25 lbs / 1.0 kg |
| Carton Quantity | 10 pieces |
| Standards | ANSI C82.11-1993, ANSI C62.41-1991, FCC Part 18 Class A (non-consumer) |
| Listing | cULus Listed – Class P, Type 1 Outdoor |
| Warranty | 5 years from date of manufacture, properly installed under normal conditions |
| Country of Manufacture | North America |
Product Overview
This AccuStart5® ballast uses programmed rapid start with active power factor correction and auto-reset end-of-lamp-life shutdown circuitry, so it automatically resumes normal operation once a failed lamp is replaced. Because this ballast uses series lamp wiring rather than parallel, both lamps in a 2-lamp fixture are electrically linked – removing or losing one lamp can affect operation of the other, unlike a parallel-wired ballast where lamps run independently.
Electrical performance varies by lamp type, lamp count, and line voltage. The table below summarizes input watts and ballast factor for each certified lamp family at both 120V and 277V; THD stays under 10% and power factor stays above .94 across every documented configuration. The 1-lamp FT36W/2G11 configuration runs a ballast factor of 1.20 – the manufacturer notes to consult the lamp manufacturer before using this ballast in applications requiring ballast factor above 1.20.
| Lamp Type | Lamps | Input Watts (120V/277V) | Ballast Factor |
| F54T5HO | 2 | 116W / 113W | 1.00 |
| F54T5HO | 1 | 59W / 59W | 1.00 |
| F54T5HO/ES (47W) | 2 | 102W / 99W | 1.00 |
| F54T5HO/ES (47W) | 1 | 54W / 53W | 1.00 |
| F54T5HO/ES (49W) | 2 | 105W / 102W | 1.00 |
| F54T5HO/ES (49W) | 1 | 54W / 53W | 1.00 |
| F54T5HO/ES (51W) | 2 | 107W / 103W | 1.00 |
| F54T5HO/ES (51W) | 1 | 55W / 55W | 1.00 |
| F58T8 | 2 | 110W / 107W | 0.90 |
| F58T8 | 1 | 56W / 56W | 0.90 |
| FT55W/2G11 | 2 | 112W / 109W | 1.00 |
| FT55W/2G11 | 1 | 56W / 56W | 1.00 |
| FT50W/2G11 | 2 | 111W / 108W | 1.00 |
| FT50W/2G11 | 1 | 57W / 57W | 1.00 |
| FC12T5-55W | 2 | 107W / 104W | 1.00 |
| FC12T5-55W | 1 | 55W / 55W | 1.00 |
| FT36W/2G11 | 2 | 89W / 83W | 1.10 |
| FT36W/2G11* | 1 | 44W / 44W | 1.20 |
*Consult lamp manufacturer for applications with ballast factor above 1.20.
Compatible Applications
- Fixtures using 1 or 2 F54T5HO, F54T5HO/ES (47W, 49W, or 51W), F58T8, FT55W/2G11, FT50W/2G11, FT36W/2G11, or FC12T5-55W lamps
- Mixed-voltage commercial buildings running 120-277VAC branch circuits
- Installations requiring 125VDC input operation
- Remote-mount applications up to 20 feet
Before Ordering – Verify
- Confirm your lamp type and count against the table above for expected input watts and ballast factor
- This is a series-wired ballast – verify your fixture's socket wiring matches series-lamp operation, not parallel
- For one-lamp operation, cap the yellow leads individually per the ballast's wiring diagram
- Confirm minimum ambient starting temperature: 0°F standard, or -20°F if the ballast will not be remote mounted
- Contact the factory before using this ballast in a tandem wiring configuration
Safety and Handling Guidelines
- Disconnect and lock out power before installing, wiring, or servicing this ballast
- Ground to case or input terminal (G) per the wiring diagram
- Do not exceed the 167°F/75°C maximum case temperature during operation
- For one-lamp operation, cap yellow leads individually rather than leaving them exposed
Compliance
- Meets ANSI C82.11-1993 and ANSI C62.41-1991
- Meets FCC Part 18 (Class A) for EMI and RFI, non-consumer limits
- cULus Listed – Class P, Type 1 Outdoor
- No PCBs
Ordering Information
- Model Number: B254PUNV-D
- Lamp Compatibility: 1 or 2 lamps across multiple T5HO/T8/2G11 families (see table above)
- Mounting: 16.28" center-to-center studs, must be grounded
For wholesale pricing, bulk availability, or help confirming the correct replacement ballast, contact ADL Supply at 1-800-235-3489.