GE 88452 FLK/LL 575W – 575W/120V Quartzline Halogen SSTV Lamp | ANSI FLK | 3100K | 12,800 Lumens | G9.5 Base
12,800 lumens at 3100K with CRI 100 – a 575W/120V Quartzline halogen SSTV lamp with G9.5 base and 1500-hour long life for film, broadcast, and stage lighting.
|
Wattage / Voltage
575W / 120V
Quartzline Halogen
|
ANSI Code
FLK
SSTV Stage
|
Initial Lumens
12,800
lm
|
Color Temp
3100K
Studio White
|
Base Type
G9.5
Two-Pin
|
Quick Specs
- Brand: GE (General Electric)
- SKU / Order Code: G39730/88452
- ANSI Code: FLK
- Lamp Type: Quartzline Halogen (SSTV)
- Wattage: 575W
- Voltage: 120V
- Base Type: G9.5
- Color Temperature: 3100K
- CRI: 100
- Initial Lumens: 12,800 lm
- Rated Average Life: 1500 hours
- Maximum Overall Length (MOL): 4.0 in
- Bulb Diameter: 0.78 in
- Burn Position: Universal
Product Overview
The GE 88452 FLK/LL Quartzline Halogen Lamp is a 575-watt, 120-volt SSTV lamp delivering 12,800 initial lumens at 3100K with CRI 100. It is designed for professional film, broadcast, stage, and studio lighting fixtures requiring a G9.5 two-pin base. The 3100K color temperature provides a slightly warmer studio white, while the 1500-hour rated life significantly reduces maintenance frequency compared to standard 300-500 hour stage lamps.
The G9.5 base is a standard for many ellipsoidal spotlights and Fresnel fixtures, ensuring secure electrical contact and precise optical alignment. With a universal burn position, this lamp adapts to base-up, base-down, or horizontal fixture orientations, offering flexibility in rigging and production environments.
Why Choose This Product
- 12,800 lumens – high output for 575W: Efficient halogen source delivering excellent brightness for key, fill, and backlighting in studio and stage applications.
- ANSI FLK – industry-standard replacement: The FLK code guarantees consistent electrical and photometric performance for compatible fixtures.
- 3100K studio white – warm broadcast color: Slightly warmer than 3200K, providing a natural tungsten ambiance while remaining camera-friendly.
- CRI 100 – perfect color rendering: Full-spectrum halogen light ensures accurate color reproduction for film, video, and live events.
- 1500-hour long life – lower maintenance: Significantly longer than many 575W stage lamps, reducing relamping costs and downtime.
- Universal burn position: Works in any orientation – base-up, base-down, or horizontal – for maximum fixture compatibility.
- G9.5 two-pin base: Industry-standard for ellipsoidal spotlights, Fresnels, and follow spots from major manufacturers.
Technical Specifications
| Brand | GE (General Electric) |
| Model / SKU | 88452 / G39730 |
| ANSI Code | FLK |
| Lamp Type | Quartzline Halogen (SSTV) |
| Wattage | 575 W |
| Voltage | 120 V |
| Base | G9.5 (Two-Pin) |
| Color Temperature | 3100K |
| CRI | 100 |
| Initial Lumens | 12,800 lm |
| Rated Average Life | 1500 hours |
| Filament Type | Verify with manufacturer specification sheet |
| Burn Position | Universal |
| Finish | Clear |
| Special Features | Quartzline, long-life (LL), universal burn |
Dimensions
| Maximum Overall Length (MOL) | 4.0 in (101.6 mm) |
| Bulb Diameter | 0.78 in (19.8 mm) |
Applications
- Film and broadcast lighting – Fresnel, open-face, and ellipsoidal spotlights
- Stage and theater fixtures – ellipsoidal spotlights (ETC Source Four, Altman, Strand)
- Studio and entertainment production – key, fill, and backlighting
- Concert and live event lighting systems
Compatibility & Replacement
Fixture type: This ANSI FLK lamp fits professional stage and studio fixtures designed for a G9.5 two-pin base and 575W/120V halogen lamps. Common in ETC Source Four ellipsoidal spotlights, Altman 360Q, Strand Lekolite, and similar fixtures.
Base: G9.5 – a two-pin base with 9.5mm spacing between contacts. Standard in many ellipsoidal spotlights and Fresnel fixtures.
Ballast: No ballast required – operates directly on 120V mains power.
Before ordering, confirm:
- ANSI code – FLK: Verify your fixture specifies ANSI FLK or equivalent 575W/120V G9.5 halogen lamp.
- Voltage – 120V: Verify fixture and supply circuit are 120V.
- Base type – G9.5: Confirm your fixture uses G9.5 lampholders (not G9.5 with different orientation or GY9.5).
- Physical dimensions: Verify your fixture accepts a lamp with 4.0-inch overall length and 0.78-inch bulb diameter.
- Burn position – universal: This lamp works in any orientation, but always follow fixture manufacturer guidelines.
- Fixture wattage rating: Ensure fixture is rated for at least 575W.
Ordering Information
- Brand: GE (General Electric)
- SKU / Order Code: G39730/88452
- ANSI Code: FLK
- Lamp Type: 575W/120V Quartzline Halogen – G9.5 Base, 3100K, 12,800 lm, 1500 hr life
- Case quantities and bulk pricing available – contact ADL Supply for volume orders.
Compliance & Certifications
- Verify UL / ETL listing status with manufacturer specification sheet.
- Verify RoHS compliance status with manufacturer specification sheet.
- Verify FDA radiation performance compliance with manufacturer specification sheet.
- Verify Prop 65 warning requirements with manufacturer specification sheet.
ADL Supply recommends confirming all applicable compliance data with the GE official product data sheet (ANSI FLK / SKU G39730) prior to specification or installation.
Safety & Handling Notes
- High pressure warning – face shield required: Quartzline lamps operate under high internal pressure. Always wear a face shield and protective gloves during handling and installation. Lamp burst can cause serious injury.
- No bare hands: Never touch the quartz envelope with bare skin. Oils cause hot spots leading to premature failure or lamp burst. Use clean gloves or a lint-free cloth.
- Do not exceed rated voltage: Operating above 120V dramatically shortens lamp life. Verify supply voltage before installing.
- Burn position – universal: This lamp is rated for universal operation, but always follow your fixture manufacturer's specified orientation.
- Extreme heat and UV output: Use only in approved enclosed luminaires with appropriate UV filtering.
- Allow complete cool-down before handling: Allow lamp to cool completely before relamping. Do not touch immediately after switching off.
- Follow your fixture manufacturer's service documentation for lamp replacement procedures.