Sylvania 49130 QTP2X54T5HO/UNV PSN

(No reviews yet) Write a Review
$37.69
SKU:
SFB49130
UPC:
46135491306
Condition:
New
Shipping:
Calculated at Checkout
HS Tariff code:
8504.10.0000

Product Overview

Sylvania logo

Sylvania 49130 QTP2x54T5HO/UNV PSN QUICKTRONIC ProStart 1-2 Lamp F54T5HO 120-277V Programmed Start Ballast

The Sylvania 49130 QTP2x54T5HO/UNV PSN is the leaded-wire version of the QUICKTRONIC ProStart T5HO universal-voltage ballast for one- or two-lamp F54T5HO applications. It operates from 120-277V, uses programmed start operation, and provides a normal 1.00 ballast factor. The ballast also supports compatible FT55DL, FPC55, and L58T8 lamp types. Verify lamp type, lamp count, ballast wiring, and enclosure dimensions before ordering.

VOLTAGE
120-277V
Universal Input
LAMP COUNT
1 or 2
F54T5HO
START TYPE
Programmed
ProStart
BALLAST FACTOR
1.00
Normal Output
THD
<10%
Low Harmonic

Technical Specifications

Brand Sylvania / OSRAM Sylvania
Item Number 49130
Ordering Abbreviation QTP2x54T5HO/UNV PSN
Series QUICKTRONIC ProStart T5HO Universal
Model Configuration Leaded / wired model
Primary Lamp Type FP54T5HO / F54T5HO
Number of Lamps 1 or 2
Also Operates FT55DL, FPC55, L58T8
Input Voltage 120-277V AC
Voltage Tolerance ±10% of rated input
Input Frequency 50/60 Hz
Starting Method Programmed Start
Circuit Type Series
Ballast Factor 1.00
Input Current 1.00A at 120V / 0.43A at 277V
System Lumens 10,000 lumens with 2 lamps; 5,000 lumens with 1 lamp
Input System Power 121/118W with 2 lamps; 61W with 1 lamp
System Efficacy 83/85 lm/W with 2 lamps; 82 lm/W with 1 lamp
Lamp Frequency >40 kHz
Lamp CCF Less than 1.6
Total Harmonic Distortion <10%
Power Factor >98%
Minimum Starting Temperature -20°F (-29°C) for QTP2x54T5HO models
Maximum Case Temperature 70°C
Remote Mounting Red leads up to 18 ft; keep blue leads under 10 ft
Dimensions 16.73 in L × 1.18 in W × 0.87 in H
Mounting Length 16.34 in
Package Quantity 10 pieces for leaded model
Certifications UL Listed Class P, Type 1 Outdoor, Type CC; CSA Certified; FCC 47 CFR Part 18 Non-Consumer
Sound Rating Class A
Transient Protection ANSI C62.41 Category A
Safety Technology QUICKSENSE dynamic end-of-lamp-life sensing with auto reset after lamp replacement

Product Overview

Sylvania QUICKTRONIC ProStart T5HO ballasts are designed for PENTRON HO, PENTRON HO Circline, and DULUX L T5 fluorescent systems. The 49130 leaded model supports one- or two-lamp operation and provides full lumen output with a normal 1.00 ballast factor.

PROStart programmed-start technology provides controlled lamp starting for applications with frequent switching, including occupancy sensors and building control systems. QUICKSENSE technology monitors lamp end-of-life conditions and shuts the system down to help protect lamp bases and sockets.

Compatible Applications

  • Commercial and retail lighting
  • Hospitality and institutional facilities
  • New construction
  • Direct and indirect lighting
  • Surface-mount fixtures
  • Cove lighting
  • Occupancy-sensor applications
  • Building lighting control systems

Before Ordering – Verify

  • Confirm manufacturer item number 49130 and QTP2x54T5HO/UNV PSN configuration.
  • Confirm that a leaded/wired ballast is required; item 49130 is the leaded version associated with item 49131.
  • Confirm the lamp is F54T5HO / FP54T5HO or another manufacturer-approved compatible lamp type.
  • Confirm whether the fixture will operate one or two lamps.
  • Verify 120-277V input voltage.
  • Confirm the 16.73 in × 1.18 in × 0.87 in ballast enclosure fits the fixture.
  • Verify the 16.34 in mounting length.
  • For remote wiring, keep red leads within 18 ft and blue leads under 10 ft.

Safety and Handling Guidelines

  • Disconnect power before installation, inspection, or service.
  • Install according to the ballast wiring diagram, NEC requirements, and applicable electrical codes.
  • Maintain proper ballast grounding.
  • Do not exceed the manufacturer remote-mount wiring limits.
  • Operation below 50°F may affect lamp output or lamp operation even though the QTP2x54T5HO model is rated for starting down to -20°F.
  • Use lamp types and lamp quantities approved for this ballast configuration.

Compliance

  • UL Listed Class P
  • Type 1 Outdoor
  • UL Type CC
  • CSA Certified
  • FCC 47 CFR Part 18 Non-Consumer
  • Class A sound rating
  • ANSI C62.41 Category A transient protection

Ordering Information

  • Manufacturer item number: 49130
  • Ordering abbreviation: QTP2x54T5HO/UNV PSN
  • Configuration: Leaded-wire model
  • Primary lamp: F54T5HO / FP54T5HO
  • Lamp quantity: 1 or 2
  • Package quantity: 10 pieces
  • Series: QUICKTRONIC ProStart T5HO Universal
  • QUICKTRONIC products are covered by the QUICK 60+ system warranty; refer to the manufacturer warranty bulletin for terms and conditions.

For wholesale pricing, bulk availability, or help confirming the correct replacement ballast, contact ADL Supply at 1-800-235-3489.

Reviews