Universal B232IUNVHP-N T8 Ballast

(1 review) Write a Review
$14.42
SKU:
UFVIB232IUNVHP-03
UPC:
768386550617
Condition:
New
Availability:
In Stock
Shipping:
Calculated at Checkout
HS Tariff code:
8504.10.0000

Product Overview

Universal Lighting Technologies Triad Logo

Universal Triad B232IUNVHP-N Electronic Instant-Start T8 Ballast – 1 or 2 Lamp, 108-305VAC

The Universal Triad® B232IUNVHP-N is a high-frequency electronic instant-start ballast built to drive 1 or 2 T8 linear fluorescent lamps (or equivalent U-shaped lamps) across a wide 108-305VAC input range, and can also operate on 140VDC input. It uses parallel lamp wiring, active power factor correction, and anti-striation circuitry, and is certified for F32T8, F32T8ES, F28T8, F25T8, F25T8ES, F17T8, F15T8, F11T8, and F40T8 lamps.

Lamp Load
1 or 2
T8 Lamps
Input Voltage
108-305V
AC (+140VDC)
Start Type
Instant
Shunted Sockets Req'd
Circuitry
Parallel
Independent Lamps
Max Case Temp
167°F
75°C

Technical Specifications

Model Number B232IUNVHP-N
Brand Universal Lighting Technologies (Triad® series)
Ballast Type High-frequency electronic, instant start
Line Voltage 108VAC-305VAC, 50/60Hz; also operates on 140VDC input, (+)L (-)N
Circuit Parallel lamp operation
Power Factor >.96 to >.99 depending on lamp type/count/voltage (active PFC)
Ballast Factor .78 to 1.14 depending on lamp type/count/voltage – see lamp table below
Total Harmonic Distortion <10% for most configurations (one 2-lamp F11T8/277V configuration is <15%)
Crest Factor <1.7
Minimum Starting Temperature 0°F / -18°C standard; 60°F / 16°C for ES & 28W lamps; 32°F / 0°C for F40T8
Maximum Case Temperature 167°F / 75°C
Sound Rating A
Remote Mounting Up to 18 ft. max lead length, 18 AWG; no remote/tandem wiring for ES lamps
Mounting Length 8.9" ±0.01" / 226mm (center-to-center mounting holes)
Overall Length 9.5" ±0.01" / 241.3mm
Width 1.31" +0.03"/-0.02" / 33.3mm
Height 1.00" +0.04"/-0.01" / 25.4mm
Weight .89 lbs
Carton Quantity 10
Standards ANSI C82.11-2011, ANSI C62.41-2002, FCC Part 18 Class A (non-consumer), CSA Standard C654 (ballast efficiency)
Listing cULus Listed – Class P, Type 1 Outdoor, Type HL
Warranty 5 years from date of manufacture, properly installed under normal conditions
Country of Manufacture North America

Product Overview

This Triad® ballast uses anti-striation circuitry to suppress standing-wave gas resonance inside the lamp envelope – important for driving modern low-mercury tri-phosphor and energy-saving lamps cleanly. Parallel lamp wiring means that in a 2-lamp fixture, one lamp failing or being removed doesn't take the other lamp down with it.

Electrical performance varies by lamp type, lamp count, and line voltage. The table below summarizes input watts and ballast factor for each certified lamp type at both 120V and 277V; power factor stays above .96 in every configuration and THD stays under 10% except for the 2-lamp F11T8/277V configuration, which runs under 15%.

Lamp Type Lamps Input Watts (120V/277V) Ballast Factor (120V/277V)
F32T8 2 55W / 55W .86 / .86
F32T8 1 35W / 34W 1.04 / 1.04
F32T8ES (30W) 2 53W / 51W .86 / .86
F32T8ES (30W) 1 33W / 32W 1.02 / 1.03
F32T8ES (25W) 2 43W / 42W .78 / .78
F32T8ES (25W) 1 27W / 26W .96 / .96
F28T8 2 48W / 46W .83 / .83
F28T8 1 30W / 29W .99 / 1.00
F25T8 2 44W / 43W .90 / .90
F25T8 1 28W / 28W 1.05 / 1.05
F25T8ES (22W) 2 37W / 36W .89 / .89
F25T8ES (22W) 1 25W / 23W 1.14 / 1.14
F17T8 2 31W / 31W .89 / .89
F17T8 1 21W / 21W 1.07 / 1.07
F15T8 2 25W / 25W .86 / .86
F15T8 1 16W / – 1.02 / –
F11T8 2 20W / 21W .78 / .78
F11T8 1 14W / – .90 / –
F40T8 1 44W / 43W 1.03 / 1.03

"–" indicates that configuration is not published in the manufacturer's data. Also compatible with equivalent U-shaped (U-bend) T8 lamps in the same wattages.

Compatible Applications

  • Fixtures using 1 or 2 F32T8, F32T8ES, F28T8, F25T8, F25T8ES, F17T8, F15T8, F11T8, or (1) F40T8 lamp(s), including equivalent U-shaped lamps
  • Mixed-voltage commercial buildings running 108-305VAC branch circuits without manual voltage selection
  • Installations requiring 140VDC input operation
  • Remote-mount applications up to 18 feet of 18 AWG lead wire (standard lamps only – not for ES lamps)

Before Ordering – Verify

  • This is an instant-start ballast – shunted bi-pin lampholders are required at all lamp socket positions. Non-shunted sockets left over from programmed-start or magnetic installations will prevent ignition
  • Confirm minimum ambient temperature at the fixture: standard lamps start to 0°F, but energy-saving/28W lamps require 60°F minimum, and F40T8 requires 32°F minimum
  • Energy-saving (ES) lamps cannot be used in remote or tandem wiring configurations – direct-wired fixture installation only for those lamp types
  • Confirm your lamp type and count against the table above for expected input watts and ballast factor
  • Confirm exact factory lead lengths for your build/order suffix directly with the manufacturer spec sheet if lead length is critical for your installation – this datasheet's lead-length table could not be reliably read for this specific build variant

Safety and Handling Guidelines

  • Disconnect and lock out power before installing, wiring, or servicing this ballast
  • Ballast must be grounded – mount the metal casing flush against the fixture's steel tray using the 8.9" center-to-center mounting holes for a proper low-impedance ground path
  • Do not exceed the 167°F/75°C maximum case temperature during operation
  • Cap and insulate the unused blue lead to 600 volts for single-lamp applications

Compliance

  • Meets ANSI C82.11-2011 and ANSI C62.41-2002
  • Meets FCC Part 18 (Class A) for EMI and RFI, non-consumer limits
  • Meets CSA Standard C654 for ballast efficiency
  • cULus Listed – Class P, Type 1 Outdoor, Type HL
  • No PCBs

Ordering Information

  • Model Number: B232IUNVHP-N
  • Lamp Compatibility: 1 or 2 T8 linear or U-shaped lamps (see table above)
  • Mounting: 8.9" center-to-center studs, must be grounded

For wholesale pricing, bulk availability, or help confirming the correct replacement ballast, contact ADL Supply at 1-800-235-3489.