Product Overview

GE 39769 FEL Q1000/4CL – 1000W/120V Quartzline Halogen SSTV Lamp | ANSI FEL | 27,500 Lumens | G9.5 Base | 3200K
27,500 lumens at 3200K with CRI 100 – a high-output 1000W/120V Quartzline halogen SSTV lamp with G9.5 medium two-pin base, T-6 bulb, CC-8 filament, and universal burn position for film, broadcast, stage, and studio lighting.
|
Wattage / Voltage
1000W / 120V
Quartzline Halogen
|
ANSI Code
FEL
SSTV Stage
|
Initial Lumens
27,500
lm
|
Color Temp
3200K
Studio White
|
Base Type
G9.5
Medium 2-Pin Prefocus
|
Quick Specs
- Brand: GE (General Electric)
- Manufacturer Part Number: 39769
- GE Product Code: 88625
- Reorder Code: BC1638
- Order Codes: Q1000/4CL, Q10004CL, Q1000 4CL, Q1000-4CL
- ANSI Code: FEL
- Lamp Type: Quartzline Halogen (SSTV)
- Wattage: 1000 W
- Voltage: 120 V
- Base Type: G9.5 (Medium 2-Pin Prefocus)
- Bulb Shape: T-6
- Bulb Finish: Clear
- Color Temperature: 3200K
- CRI: 100
- Initial Lumens: 27,500 lm
- Rated Average Life: 300 hours
- Filament Type: CC-8
- Burn Position: Universal
- Maximum Overall Length (MOL): 4.130 in (104.9 mm)
- Bulb Diameter: 0.750 in (19.1 mm)
- Light Center Length (LCL): 2.370 in (60.2 mm)
Product Overview
The GE 39769 FEL Quartzline Halogen Lamp is a 1000-watt, 120-volt SSTV lamp delivering 27,500 initial lumens at 3200K studio white with CRI 100. It features a G9.5 medium two-pin prefocus base and a T-6 clear bulb, making it a professional choice for film and broadcast lighting, stage and studio fixtures, and entertainment production.
The CC-8 filament provides stable, intense light output, while the 300-hour rated life is optimized for applications where maximum brightness per watt is prioritized over extended life – ideal for high-intensity follow spots, ellipsoidal spotlights, and Fresnel fixtures. The universal burn position allows installation in base-up, base-down, or horizontal fixtures without restriction. With a compact T-6 envelope (4.130-inch MOL, 0.750-inch diameter) and precise 2.370-inch light center length, this ANSI FEL lamp is a direct replacement for compatible professional luminaires.
Why Choose This Product
- 27,500 lumens – high-output 1000W halogen: Excellent brightness for key lighting, follow spots, ellipsoidal spotlights, and studio production.
- ANSI FEL – industry-standard replacement: The FEL code guarantees consistent electrical and photometric performance for compatible fixtures.
- 3200K studio white – broadcast-matched color: Camera systems set to 3200K tungsten white balance reproduce colors accurately under this lamp.
- CRI 100 – perfect color rendering: Full-spectrum halogen light ensures accurate color reproduction for film, video, and live events.
- Universal burn position: Works in any orientation – base-up, base-down, or horizontal – for maximum fixture compatibility.
- G9.5 prefocus base: Ensures repeatable optical alignment in ellipsoidal spotlights, follow spots, and projection fixtures.
Technical Specifications
| Brand | GE (General Electric) |
| Model / Part Number | 39769 / 88625 |
| Reorder Code | BC1638 |
| ANSI Code | FEL |
| Lamp Type | Quartzline Halogen (SSTV) |
| Wattage | 1000 W |
| Voltage | 120 V |
| Base | G9.5 (Medium 2-Pin Prefocus) |
| Bulb Shape | T-6 |
| Bulb Finish | Clear |
| Color Temperature | 3200K |
| CRI | 100 |
| Initial Lumens | 27,500 lm |
| Rated Average Life | 300 hours |
| Filament Type | CC-8 |
| Burn Position | Universal |
Dimensions
| Maximum Overall Length (MOL) | 4.130 in (104.9 mm) |
| Bulb Diameter | 0.750 in (19.1 mm) |
| Light Center Length (LCL) | 2.370 in (60.2 mm) |
Applications
- Film and broadcast lighting – Fresnel and open-face fixtures
- Stage and theater – ellipsoidal spotlights, follow spots, lekos
- Studio and entertainment production – key, fill, and backlighting for television and video
- Concert and live event lighting – high-intensity spotlights and wash fixtures
Compatibility & Replacement
Fixture type: This ANSI FEL lamp fits professional stage, studio, and broadcast fixtures designed for a G9.5 medium two-pin prefocus base and 1000W/120V halogen lamps. Common in ellipsoidal spotlights (e.g., Altman 360Q, ETC Source Four with adapter), follow spots, and Fresnel fixtures from manufacturers such as Altman, Strand, and Kliegl.
Base: G9.5 – a two-pin prefocus base with 9.5mm spacing between contacts. Standard in many ellipsoidal spotlights and follow spots.
Ballast: No ballast required – operates directly on 120V mains power.
Before ordering, confirm:
- ANSI code – FEL: Verify your fixture specifies ANSI FEL or equivalent 1000W/120V G9.5 halogen lamp.
- Voltage – 120V: Verify fixture and supply circuit are 120V.
- Base type – G9.5: Confirm your fixture uses G9.5 prefocus lampholders (not GY9.5 or other variants).
- Physical dimensions: Verify your fixture accepts a T-6 bulb with 4.130-inch MOL, 0.750-inch diameter, and 2.370-inch LCL.
- Fixture wattage rating: Ensure fixture is rated for at least 1000W.
- Burn position – universal: This lamp works in any orientation, but always follow fixture manufacturer guidelines.
Ordering Information
- Brand: GE (General Electric)
- Manufacturer Part Number: 39769
- GE Product Code: 88625
- Reorder Code: BC1638
- ANSI Code: FEL
- Lamp Type: 1000W/120V Quartzline Halogen – G9.5 Base, T-6, Clear, 3200K, 27,500 lm, 300 hr life, universal burn
- Case quantities and bulk pricing available – contact ADL Supply for volume orders.
Compliance & Certifications
- Verify UL / ETL listing status with manufacturer specification sheet.
- Verify RoHS compliance status with manufacturer specification sheet.
- Verify FDA radiation performance compliance with manufacturer specification sheet.
- Verify Prop 65 warning requirements with manufacturer specification sheet.
ADL Supply recommends confirming all applicable compliance data with the GE official product data sheet (ANSI FEL / Part # 39769) prior to specification or installation.
Safety & Handling Notes
- High pressure warning – face shield required: Quartzline halogen lamps operate under high internal pressure. Always wear a face shield and protective gloves during handling and installation. Lamp burst can cause serious injury.
- No bare hands: Never touch the quartz envelope with bare skin. Oils cause hot spots leading to premature failure or lamp burst. Use clean gloves or a lint-free cloth.
- Do not exceed rated voltage: Operating above 120V dramatically shortens lamp life. Verify supply voltage before installing.
- Burn position – universal: This lamp is rated for universal operation, but always follow your fixture manufacturer's specified orientation.
- Extreme heat and UV output: Use only in approved enclosed luminaires with appropriate UV filtering.
- Allow complete cool-down before handling: Allow lamp to cool completely before relamping. Do not touch immediately after switching off.
- Follow your fixture manufacturer's service documentation for lamp replacement procedures.