Universal Lighting Technologies M7012/27CK-5EU-JT3 – 70W Metal Halide Electronic Ballast | 120/277V | Low Frequency Square Wave | 120V IDTP Tap | Order Code 188631
The Universal Lighting Technologies M7012/27CK-5EU-JT3 (ballast order code 188631) is a microprocessor-controlled electronic low frequency square wave ballast for a single 70W metal halide lamp, covering ANSI types M98, M139, and M143. It accepts 120 or 277 VAC at ±10%, 50/60 Hz, uses resonance start with active power factor correction, and holds a 1.00 ballast factor with power factor above 95%. The distinguishing feature is the 120V "tap", which supplies 120V to the heaters of 3-wire or 4-wire self-heating thermal protectors (IDTPs) — and the tap lead can be capped off so the unit runs as a conventional HID ballast across the full 120V to 277V input range.
|
Lamp Watts
70W
M98 / M139 / M143
|
Input Voltage
120/277V
±10%, 50/60 Hz
|
Ballast Factor
1.00
Power Factor >95%
|
Max Case Temp
80°C
-15°C Min Start
|
Remote Mount
15 ft
Conduit Required
|
Technical Specifications
| Brand | Universal Lighting Technologies |
| Model | M7012/27CK-5EU-JT3 |
| Ballast Order Code | 188631 |
| Ballast Type | Electronic, low frequency square wave, microprocessor controlled |
| Lamp Type | 70W metal halide |
| ANSI Lamp Types | M/C98, M/C139, M/C143 |
| Number of Lamps | 1 |
| Starting Method | Resonance start |
| Line Voltage | 120/277 VAC, ±10%, 50/60 Hz |
| Ballast Factor | 1.00 |
| Power Factor | Greater than 95%, with active power factor correction |
| Crest Factor | Less than 1.5 |
| Input Watts — 120V, tap capped off | 79 W |
| Input Watts — 277V, tap capped off | 78 W |
| Input Watts — 120V, with IDTP | 81 W |
| Input Watts — 277V, with IDTP | 80 W |
| Nominal Line Amps — 120V | 0.67 A without IDTP, 0.69 A with IDTP |
| Nominal Line Amps — 277V | 0.29 A without IDTP, 0.30 A with IDTP |
| Total Harmonic Distortion — 120V | Less than 6% |
| Total Harmonic Distortion — 277V | Less than 12% |
| IDTP Tap Function | Provides 120V to the heaters of integral dual thermal protectors; compatible with 3-wire and 4-wire IDTPs |
| IDTP Voltage Rating | Operation with IDTP is dual voltage rated for 120V or 277V |
| Operation Without IDTP | May be operated as a normal HID ballast with the tap lead capped off, across the entire 120V to 277V input voltage range |
| Abnormal Operation Shutdown | Yes — line voltage must be cycled to reset |
| End-of-Life Protection | Yes |
| Thermal Protection | Yes |
| Minimum Starting Temperature | -15 °C / +5 °F |
| Maximum Case Temperature | 80 °C / 176 °F |
| Sound Rating | A |
| Maximum Remote Mounting Distance | 15 ft, subject to the conduit and wiring requirements below |
| Mounting Type | Studs, top lead exit — 8-32 studs on 2.0 in. / 50.8 mm centers |
| Overall Length | 5.02 in. / 127.5 mm |
| Width | 3.62 in. / 92.0 mm |
| Height | 1.57 in. / 39.9 mm |
| Weight | 20 oz |
| Lead Lengths | 7 in. / 178 mm, all leads |
| Lead Stripping | 0.375 in. / 9.53 mm, tinned, all leads |
| Country of Manufacture | North America |
| Warranty | 3 years from date of manufacture, based on normal operation of 4,000 hours per year |
Product Overview
This is a low frequency square wave ballast, which is the design approach used for metal halide specifically to avoid acoustic resonance in the arc tube. Rather than running the lamp at high frequency the way a fluorescent electronic ballast does, it delivers a low frequency square wave that keeps the arc stable and protects color consistency over lamp life. Microprocessor control handles regulation, and active power factor correction holds power factor above 95% at both 120V and 277V.
The reason this particular model exists is the 120V tap. Many enclosed and outdoor metal halide fixtures use a self-heating integral dual thermal protector, which needs a 120V feed to its heater element regardless of what voltage the ballast itself is running on. This ballast supplies that feed, is compatible with both 3-wire and 4-wire IDTPs, and remains dual voltage rated for 120V or 277V operation when the IDTP is in use. If the fixture has no IDTP, the tap lead is simply capped off and the unit works as a conventional HID ballast anywhere in the 120V to 277V range — so one part number covers both cases.
Protection is layered: end-of-life detection, thermal protection, and an abnormal operation shutdown circuit. Note that the shutdown circuit latches — line voltage has to be cycled to reset it, which is deliberate, since it forces someone to look at the fixture rather than letting it cycle unattended. The unit is cULus listed for outdoor Type 1 use, sound rated A, contains no PCBs, and is RoHS compliant. It mounts on 8-32 studs with top lead exit in a 5.02 by 3.62 by 1.57 inch case.
Compatible Applications
- 70W metal halide fixtures using ANSI M98, M139, or M143 lamps
- Enclosed and outdoor fixtures fitted with 3-wire or 4-wire self-heating thermal protectors
- Parking lot, area, and street lighting on 120V or 277V distribution
- Wall packs, canopy lights, and building-mounted floodlights
- Industrial and commercial HID fixtures
- Retrofit replacement of a failed 70W magnetic or electronic HID ballast
- Fixtures without an IDTP, by capping off the tap lead
- Remote-mounted ballast installations up to 15 ft, where the lamp leads can be run in dedicated conduit
Before Ordering – Verify
- Confirm the lamp is a 70W metal halide of ANSI type M98, M139, or M143. This ballast is not rated for other wattages or for pulse start types outside those ANSI designations.
- Confirm whether the fixture uses an IDTP. If it does, verify it is a 3-wire or 4-wire self-heating type. If it does not, the tap lead is capped off and the ballast operates normally.
- For remote mounting, confirm the wiring method before ordering. Each lamp’s lead wires must run in a separate conduit of at least 1/2 in. inside diameter, kept apart from the input leads. Extension wiring must use individual, unbundled SF-2 or SFF-2 wire or equivalent. Power cords and MC cable are not acceptable extension wiring methods.
- Confirm the supply voltage is 120V or 277V, within ±10%.
- Confirm the mounting pattern accepts 8-32 studs on 2.0 in. centers with top lead exit.
- Confirm the fixture has clearance for a 5.02 in. x 3.62 in. x 1.57 in. case.
- Confirm the 7 in. lead length reaches the intended junction without splicing inside the fixture.
- Confirm the ambient allows starting at or above -15 °C / +5 °F and keeps case temperature at or below 80 °C / 176 °F.
- Note that the warranty period assumes 4,000 operating hours per year; longer duty adjusts the period accordingly.
Safety and Handling Guidelines
- Disconnect power at the breaker before installing, wiring, or replacing the ballast.
- Wire according to the diagram matching your configuration — 3-wire 120V IDTP, 4-wire 120V IDTP, or 3-wire 277V IDTP.
- If no IDTP is used, cap off the tap lead rather than leaving it exposed.
- Run each lamp’s lead wires in a separate minimum 1/2 in. ID conduit, away from the input leads, to achieve rated EMI performance and remote mounting distance.
- Use only individual, unbundled SF-2 or SFF-2 wire or equivalent for extension wiring. Do not use power cords or MC cable.
- If the abnormal operation shutdown circuit trips, correct the underlying fault and cycle line voltage to reset; do not repeatedly reset without investigating.
- Mount so the case stays at or below its 80 °C maximum, and do not obstruct airflow.
- Metal halide lamps operate under pressure and at high temperature; follow the lamp manufacturer’s enclosure and handling requirements.
- Installation should be performed by a qualified electrician in accordance with the National Electrical Code and local codes.
Compliance
- cULus Listed, Outdoor Type 1
- Meets ANSI Standard C82.14-2006
- Meets ANSI Standard C62.41-1991
- Meets FCC Part 18C for EMI and RFI, non-consumer
- Thermal protection
- End-of-life protection
- Contains no PCBs
- RoHS compliant
- Sound rated A
- 3-year limited warranty from date of manufacture against defects in material or workmanship, when properly installed and under normal conditions of use, based on 4,000 hours of operation per year
- Manufactured in North America
Ordering Information
- Model: M7012/27CK-5EU-JT3
- Ballast order code: 188631
- Configuration: single lamp, 70W metal halide, 120/277V, studs with top lead exit
- Includes the 120V IDTP tap lead; no IDTP, lamp, or mounting hardware is supplied
- For extended warranty periods beyond 36 months, Universal Lighting Technologies directs customers to call for fixture testing instructions
- Case and project quantities available
For wholesale pricing, bulk availability, or help confirming the correct replacement ballast, contact ADL Supply at 1-800-235-3489.