Product Overview
HALCO 80128 BR40FL18/840/LED LED BR40 17W 4000K DIMMABLE E26 PROLED
SPECIFICATIONS
Applications | Accent; Display; Retail,Education; Healthcare; Hospitality; office |
Average Life (Hrs) | 25000 |
Base | Medium |
Beam Angle | Flood |
Beam Spread | 105 |
Brand | ProLED |
Bulb | BR40 |
CRI | 82 |
Color Temperature | 4000 |
Dimensional Dwg | |
Dimmable | Yes |
ENERGY STAR | No |
Equivalent Wattage | 85 |
Finish | White |
HTS code | 8543707000 |
Initial Lumens | 1280 |
Inner Carton Quantity | 6 |
Input Frequency (Hz) | 60 |
Markets | Residential, Commercial |
Master Carton Quantity | 24 |
Maximum Overall Diameter | 5 |
Maximum Overall Length | 6.46 |
Nominal Length | 6.46 |
Operating Position | Universal |
Prod Code | BR40FL18/840/LED |
Product Category | LED |
Product Description | LED BR40 18W 4000K DIMMABLE E26 PRO |
Product Number | 80128 |
Voltage (V) | 120 |
Warranty (Yrs) | 5 |
Wattage (W) | 17 |
TECHNICAL
Base Material | Aluminum |
Dimensional Dwg | |
Footnotes 1 | Dimmable 120V lamps should only be used on 120V circuits. Lamps are designed for use with an analog dimmer and these products may not be compatible with all dimming devices. Lamps should be tested in the application prior to full installations on circuits using such devices. Not for use on timing devices, photosensors,digital dimmers or occupancy sensors. Ensure minimum dimmer load is met for best performance. |
Footnotes 2 | Caution: Risk of electric shock. Never disassemble or modify the bulb, no user serviceable parts inside.To avoid burns, do not touch the bulb during operation and allow to cool completely after switching off. This device is not intended for use in emergency exit fixtures. This device complies with Part 18 of the FCC rules. This product may cause interference with other devices. If interference occurs, change the location of the products involved. |
Footnotes 3 | Do not use where directly exposed to water. |
Footnotes 4 | Dimmable lamps dim down to 5%, but are limited by the dimming device range. |
Footnotes 5 | Not for use in totally enclosed fixtures.Acceptable for use in insulated contact airtight (ICAT) rated fixtures |
Footnotes 6 | Lamp is UL approved for damp locations. |
IP Rating | 64 |
Mercury | No |
Mercury Content (Hg) | 0 |
Minimum Starting Temperature (C) | 0 |
Prod Code | BR40FL18/840/LED |
RoHS Compliant | Yes |
UL | Yes |
UNSPSC | 39112102 |
UPC Code | 807154801282 |
Warning 1 | Rated for ICAT fixtures |
Warning 10 | Use only on 120 volts, 60-hertz frequency |
Warning 2 | Risk of electric shock |
Warning 3 | Never disassemble or modify the bulb |
Warning 4 | To avoid burns, do not touch the bulb during operation and allow to cool completely after switching off |
Warning 5 | This device is not intended for use with emergency exit fixtures |
Warning 6 | If this product causes interference with other devices, change the location of the products involved |
Warning 7 | UL rated for damp location |
Warning 8 | This dimmable lamp may not be compatible with all dimmers, timing devices, occupancy sensors, and photo sensors, please check the website www.halcolighting.com/ProLEDdim for up-to-date dimmer compatibility information |
Warning 9 | Do not use in totally enclosed fixtures |
Weight (lbs) | 0 |
cUL | Yes |